WWTP Power Generation Station
2020 Wake Avenue, Oakland, CA 94607Plant Summary Information
WWTP Power Generation Station is ranked #11 out of 74 other biomass gas power plants nationwide in terms of total annual net electricity generation.
WWTP Power Generation Station is comprised of 3 generators and generated 7.0 GWh during the 3-month period between May 2024 to August 2024.
Plant Name | WWTP Power Generation Station |
---|---|
Utility Name | East Bay Municipal Util Dist |
Location | Alameda County, CA |
Initial Operation Date | August 1985 |
Last Update | Aug 2024 |
Annual Generation | 26.9 GWh |
Annual Consumption | 377.4 k MMBtu |
Ranked #4,675 out of 11,835 Power Plants Nationwide | |
Ranked #11 out of 74 Other Biomass Gas Power Plants Nationwide | |
Ranked #645 out of 1,569 California Power Plants | |
Ranked #8 out of 37 California Other Biomass Gas Power Plants | |
Fuel Types | Other Biomass Gas : 99.0% Distillate Fuel Oil : 1.0% |
Map of WWTP Power Generation Station
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for WWTP Power Generation Station.
Monthly Net Generation for WWTP Power Generation Station
WWTP Power Generation Station Details
Summary Information | |
---|---|
Plant Name | WWTP Power Generation Station (56036) |
Plant Address | 2020 Wake Avenue, Oakland, CA 94607 |
Utility | East Bay Municipal Util Dist (5571) |
Latitude, Longitude | 37.8258, -122.2961 |
Generation Dates on File | Jan 2003 to Aug 2024 |
Initial Operation Date | August 1985 |
Annual Generation | 26.9 GWh |
Fuel Types | Other Biomass Gas : 99.0% Distillate Fuel Oil : 1.0% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | Yes |
FERC Cogeneration Docket Number | 09-321-001 |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | WECC |
Balancing Authority | California Independent System Operator (CISO) |
NAICS Code | Sewage Treatment Facilities (22132) |
Sector | Commercial CHP (5) |
Water Source | WWTP and Potable water |
Ash Impoundment | No |
Transmission / Distribution Owner | Pacific Gas & Electric Co (14328) CA |
Grid Voltage | 12.50 kV |
Energy Storage | No |
Generator GEN1 Details Operating August 1985
Technology | Other Waste Biomass |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | OAK C_1_EBMUD |
Nameplate Capacity | 2.2 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 2 MW |
Winter Capacity | 2 MW |
Minimum Load | 1.5 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 1985 |
---|---|
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Other Biomass Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | DFO / OBG |
---|
Generator GEN2 Details Operating August 1985
Technology | Other Waste Biomass |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | OAK C_1_EBMUD |
Nameplate Capacity | 2.2 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 2 MW |
Winter Capacity | 2 MW |
Minimum Load | 1.5 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 1985 |
---|---|
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Other Biomass Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | DFO / OBG |
---|
Generator GEN3 Details Operating August 1985
Technology | Other Waste Biomass |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | OAK C_1_EBMUD |
Nameplate Capacity | 2.2 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 2 MW |
Winter Capacity | 2 MW |
Minimum Load | 1.5 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 1985 |
---|---|
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Other Biomass Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | DFO / OBG |
---|
WWTP Power Generation Station Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Other Biomass Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1 | Total Energy Facilities | Carson, CA | 168.8 GWh |
#2 | Hyperion Treatment Plant CHP Plant | Playa del Rey, CA | 136.4 GWh |
#3 | Walt Bailey Bioenergy Facility | Washington, DC | 57.0 GWh |
#4 | Plant No 2 Orange County | Huntington Beach, CA | 59.0 GWh |
#5 | Cosumnes | Herald, CA | 3.8 TWh |
#6 | SJ/SC WPCP | San Jose, CA | 81.5 GWh |
#7 | Metro Wastewater Reclamation District | Denver, CO | 37.7 GWh |
#8 | Gas Utilization Facility | San Diego, CA | 32.8 GWh |
#9 | Plant No 1 Orange County | Fountain Valley, CA | 39.3 GWh |
#10 | BioTown Ag | Reynolds, IN | 30.2 GWh |
#12 | Deer Island Treatment Plant | Winthrop, MA | 37.5 GWh |
#13 | PWD Northeast WPCP Biogas Cogen Plant | Philadelphia, PA | 30.4 GWh |
#14 | MMSD South Shore Wastewater | Oak Creek, WI | 30.2 GWh |
#15 | Power Generation Station (PGS) 2 | Oakland, CA | 20.4 GWh |
#16 | Hometown Bio Energy LLC | Le Sueur, MN | 20.4 GWh |
#17 | ABEC Bidart-Old River LLC | Bakersfield, CA | 16.0 GWh |
#18 | Encina Water Pollution Control | Carlsbad, CA | 14.2 GWh |
#19 | Zeeland Farm Services | Zeeland, MI | 13.2 GWh |
#20 | Southside Water Reclamation Plant | Albuquerque, NM | 18.6 GWh |
#21 | Green Cow Power | Goshen, IN | 12.8 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding WWTP Power Generation Station.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Alameda | Alameda, CA | 3.9 GWh | 2.6 mi |
Bio-Rad | Hercules, CA | 3.3 GWh | 13.6 mi |
CA Dept of Public Health at Richmond | Richmond, CA | 3.8 GWh | 7 mi |
City of Hayward WWTP | Hayward, CA | 10.3 GWh | 15.8 mi |
Dynegy Oakland Power Plant | Oakland, CA | 9.3 GWh | 2.2 mi |
KSR028 Merced Fuel Cell | San Leandro, CA | 14.4 GWh | 10.9 mi |
Marin Clean Energy Solar One | Richmond, CA | 19.9 GWh | 9.4 mi |
Nove Power Plant | Richmond, CA | 35.0 MWh | 10.9 mi |
One Market Plaza | San Francisco, CA | 993.0 MWh | 5.8 mi |
Parnassus Central Utility Plant | San Francisco, CA | 69.3 GWh | 9.8 mi |
PE Berkeley | Berkeley, CA | 161.2 GWh | 3.6 mi |
Phillips 66 Carbon Plant | Rodeo, CA | 50.1 GWh | 13.7 mi |
Phillips 66 Rodeo Refinery | Rodeo, CA | 291.0 GWh | 15.1 mi |
Pixar - Emeryville | Emeryville, CA | 7.1 GWh | 0.8 mi |
Power Generation Station (PGS) 2 | Oakland, CA | 20.4 GWh | 0 mi |
Preferred Freezer San Leandro | San Leandro, CA | 3.2 GWh | 11.2 mi |
Richmond Cogen | Richmond, CA | 922.3 GWh | 9.5 mi |
SF Southeast Cogen Plant | San Francisco, CA | 235.0 MWh | 7.9 mi |
Sunset Reservoir North Basin | San Francisco, CA | 6.0 GWh | 11.4 mi |
Transamerica Pyramid | San Francisco, CA | 525.0 MWh | 6.2 mi |