Wansley Combined Cycle

3461 Hollingsworth Ferry Road, Franklin, GA 30217

Plant Summary Information

Wansley Combined Cycle is ranked #25 out of 2,253 natural gas power plants nationwide in terms of total annual net electricity generation.

Wansley Combined Cycle is comprised of 6 generators and generated 2.2 TWh during the 3-month period between May 2024 to August 2024.

Plant NameWansley Combined Cycle
Utility NameSouthern Power Co
LocationHeard County, GA
Initial Operation DateJune 2002
Last Update Aug 2024
Annual Generation 8.3 TWh
Annual Consumption 64.6 M MMBtu
Ranked #93 out of 11,835 Power Plants Nationwide
Ranked #25 out of 2,253 Natural Gas Power Plants Nationwide
Ranked #6 out of 238 Georgia Power Plants
Ranked #3 out of 47 Georgia Natural Gas Power Plants
Fuel Types Natural Gas

Map of Wansley Combined Cycle

Full Screen Map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Wansley Combined Cycle.

Create Your Account Today

Monthly Net Generation for Wansley Combined Cycle

Wansley Combined Cycle Details

Summary Information
Plant NameWansley Combined Cycle (55965)
Plant Address3461 Hollingsworth Ferry Road, Franklin, GA 30217
UtilitySouthern Power Co (17650)
Latitude, Longitude33.40639, -85.03699
Generation Dates on FileJun 2002 to Aug 2024
Initial Operation DateJune 2002
Annual Generation 8.3 TWh
Fuel Types Natural Gas
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusNo
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusNon-Regulated
NERC RegionSERC
Balancing AuthoritySouthern Company Services, Inc. - Trans (SOCO)
NAICS CodeUtilities (22)
Sector IPP Non-CHP (2)
Water SourceChattahoochee River
Ash Impoundment No
Transmission / Distribution OwnerGeorgia Power Co (7140) GA
Grid Voltage 500.00 kV
Energy StorageNo
 
Natural Gas Information
Pipeline Name TRANSCONTINENTAL GAS PIPELINE
Natural Gas StorageNo

Generator CT6A Details Operating June 2002

TechnologyNatural Gas Fired Combined Cycle
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeG106
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorNo
Nameplate Capacity203.1 MW
Nameplate Power Factor0.85
Summer Capacity176.8 MW
Winter Capacity189.3 MW
Minimum Load115 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2002
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator CT6B Details Operating June 2002

TechnologyNatural Gas Fired Combined Cycle
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeG106
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorNo
Nameplate Capacity203.1 MW
Nameplate Power Factor0.85
Summer Capacity176.8 MW
Winter Capacity189.3 MW
Minimum Load115 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2002
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator CT7A Details Operating June 2002

TechnologyNatural Gas Fired Combined Cycle
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeG107
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorNo
Nameplate Capacity203.1 MW
Nameplate Power Factor0.85
Summer Capacity175.6 MW
Winter Capacity187.4 MW
Minimum Load115 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2002
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator CT7B Details Operating June 2002

TechnologyNatural Gas Fired Combined Cycle
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeG107
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorNo
Nameplate Capacity203.1 MW
Nameplate Power Factor0.85
Summer Capacity175.6 MW
Winter Capacity187.4 MW
Minimum Load115 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2002
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator ST6 Details Operating June 2002

TechnologyNatural Gas Fired Combined Cycle
Prime MoverCombined Cycle Steam Part
Unit CodeG106
OwnershipSingle Owner
Duct BurnersYes
Nameplate Capacity213.3 MW
Nameplate Power Factor0.85
Summer Capacity240 MW
Winter Capacity240 MW
Minimum Load120 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2002
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator ST7 Details Operating June 2002

TechnologyNatural Gas Fired Combined Cycle
Prime MoverCombined Cycle Steam Part
Unit CodeG107
OwnershipSingle Owner
Duct BurnersYes
Nameplate Capacity213.3 MW
Nameplate Power Factor0.85
Summer Capacity240 MW
Winter Capacity240 MW
Minimum Load120 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2002
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Wansley Combined Cycle Plant Owners

Owner NameAddressGeneratorOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Natural Gas.

RankPlant NamePlant LocationAnnual Generation
#15Warren CountyFront Royal, VA9.2 TWh
#16Nine Mile PointWestwego, LA8.9 TWh
#17Fort MyersFt. Myers, FL8.9 TWh
#18Lawrenceburg Power, LLCLawrenceburg, IN8.9 TWh
#19York Energy CenterDelta, PA8.8 TWh
#20Sherwood H Smith Jr Energy ComplexHamlet, NC8.8 TWh
#21South Field EnergyWellsville, OH8.5 TWh
#22Thomas A Smith Energy FacilityDalton, GA8.5 TWh
#23SanfordDeBary, FL8.4 TWh
#24Hummel Station LLCShamokin Dam, PA8.4 TWh
#26Seminole (FL)Palatka, FL11.1 TWh
#27McIntosh Combined Cycle FacilityRincon, GA8.2 TWh
#28Brunswick County Power StationFreeman, VA7.9 TWh
#29Port Washington Generating StationPort Washington, WI7.9 TWh
#30Fairless Energy CenterFairless Hills, PA7.8 TWh
#31Indeck Niles Energy CenterNiles, MI7.7 TWh
#32Moxie Freedom Generation PlantSalem Township, PA7.7 TWh
#33Deer Park Energy CenterDeer Park, TX7.7 TWh
#34RivieraRiviera Beach, FL7.6 TWh
#35ParadiseDrakesboro, KY7.5 TWh

Nearby Power Plants

Below are closest 20 power plants surrounding Wansley Combined Cycle.

Plant NamePlant LocationAnnual GenerationDistance
Atlanta Falcons SolarAtlanta, GA1.1 GWh43.8 mi
Camp Solar PlantWoodbury, GA3.2 GWh41.8 mi
Chattahoochee Energy FacilityFranklin, GA3.3 TWh0.1 mi
GreenvilleGreenville, GA1.4 GWh31.1 mi
Harris DamLineville, AL128.9 GWh35 mi
Hawk Road FacilityFranklin, GA569.4 GWh4.2 mi
Jack McDonoughSmyrna, GA18.3 TWh43.3 mi
Kimberly-Clark SolarLaGrange, GA2.7 GWh28.1 mi
LaFayette Solar FarmLaFayette, AL166.8 GWh41.9 mi
MAS ASB Cogen PlantAtlanta, GA39.2 GWh40.8 mi
Meriwether JacksonMachester, GA5.9 GWh43 mi
RockmartRockmart, GA5.5 GWh42 mi
Sewell Creek EnergyCedartown, GA425.2 GWh39.9 mi
Tenaska Georgia Generation FacilityFranklin, GA214.0 GWh4.4 mi
Troup RC50Pine Mountain, GA4.6 GWh36.9 mi
Troup RC50 IIPine Mountain, GA2.9 GWh36 mi
Turnipseed Solar, LLCDouglasville, GA5.2 GWh28.9 mi
Wansley Unit 9Franklin, GA3.2 TWh0.2 mi
West Point (GA)West Point, GA198.7 GWh34.8 mi
YatesNewnan, GA2.2 TWh8.9 mi