University of Illinois Abbott Power Plt
1117 S Oak, Champaign, IL 61820Plant Summary Information
University of Illinois Abbott Power Plt is ranked #14 out of 72 natural gas power plants in Illinois in terms of total annual net electricity generation.
University of Illinois Abbott Power Plt is comprised of 11 generators and generated 57.0 GWh during the 3-month period between September 2023 to December 2023.
Plant Name | University of Illinois Abbott Power Plt |
---|---|
Utility Name | University of Illinois |
Location | Champaign County, IL |
Initial Operation Date | November 1940 |
Last Update | Dec 2023 |
Annual Generation | 235.0 GWh |
Annual Consumption | 3.9 M MMBtu |
Ranked #2,114 out of 11,835 Power Plants Nationwide | |
Ranked #707 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #72 out of 318 Illinois Power Plants | |
Ranked #14 out of 72 Illinois Natural Gas Power Plants | |
Fuel Types | Natural Gas : 95.7% Bituminous Coal : 4.3% |
Map of University of Illinois Abbott Power Plt
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for University of Illinois Abbott Power Plt.
Monthly Net Generation for University of Illinois Abbott Power Plt
University of Illinois Abbott Power Plt Details
Summary Information | |
---|---|
Plant Name | University of Illinois Abbott Power Plt (54780) |
Plant Address | 1117 S Oak, Champaign, IL 61820 |
Utility | University of Illinois (19528) |
Latitude, Longitude | 40.10517, -88.24153 |
Generation Dates on File | Jan 2001 to Dec 2023 |
Initial Operation Date | November 1940 |
Annual Generation | 235.0 GWh |
Fuel Types | Natural Gas : 95.7% Bituminous Coal : 4.3% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | SERC |
Balancing Authority | Midcontinent Independent Transmission System Operator, Inc.. (MISO) |
NAICS Code | Educational Services (611) |
Sector | Commercial CHP (5) |
Water Source | Illinois American Water |
Ash Impoundment | No |
Transmission / Distribution Owner | Ameren Illinois Company (56697) IL |
Grid Voltage | 69.00 kV |
Energy Storage | Yes |
Natural Gas Information | |
Local Distribution Company (LDC) | AMEREN ILLINOIS |
Pipeline Name | Other - Please explain in pipeline notes below. |
Pipeline Notes | University of Illinois |
Natural Gas Storage | No |
Liquefied Natural Gas Storage | No |
Generator T1 Details Operating November 1940
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 3 MW |
Winter Capacity | 3 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | November 1940 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 3 MW |
Net Winter Capacity With Natural Gas | 3 MW |
Net Summer Capacity With Oil | 3 MW |
Net Winter Capacity With Oil | 3 MW |
Time To Switch From Gas To Oil | 6H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T2 Details Operating November 1940
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 3 MW |
Winter Capacity | 3 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | November 1940 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 3 MW |
Net Winter Capacity With Natural Gas | 3 MW |
Net Summer Capacity With Oil | 3 MW |
Net Winter Capacity With Oil | 3 MW |
Time To Switch From Gas To Oil | 6H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T3 Details Operating November 1948
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 3 MW |
Winter Capacity | 3 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | November 1948 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 3 MW |
Net Winter Capacity With Natural Gas | 3 MW |
Net Summer Capacity With Oil | 3 MW |
Net Winter Capacity With Oil | 3 MW |
Time To Switch From Gas To Oil | 6H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T4 Details Operating February 1951
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 3 MW |
Winter Capacity | 3 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | February 1951 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 3 MW |
Net Winter Capacity With Natural Gas | 3 MW |
Net Summer Capacity With Oil | 3 MW |
Net Winter Capacity With Oil | 3 MW |
Time To Switch From Gas To Oil | 6H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T6 Details Operating June 1959
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 7.5 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 7.5 MW |
Winter Capacity | 7.5 MW |
Minimum Load | 1.5 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 1959 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO / BIT |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 7.5 MW |
Net Winter Capacity With Natural Gas | 7.5 MW |
Net Summer Capacity With Oil | 7.5 MW |
Net Winter Capacity With Oil | 7.5 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T7 Details Operating August 1962
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 7.5 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 7.5 MW |
Winter Capacity | 7.5 MW |
Minimum Load | 1.5 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 1962 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO / BIT |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 7.5 MW |
Net Winter Capacity With Natural Gas | 7.5 MW |
Net Summer Capacity With Oil | 7.5 MW |
Net Winter Capacity With Oil | 7.5 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T9 Details Operating November 2003
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 13 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 12.5 MW |
Winter Capacity | 15 MW |
Minimum Load | 7 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | November 2003 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
---|---|
Topping Or Bottoming | T |
Energy Source | Natural Gas / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Other Combustion Technology | No |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 11 MW |
Net Winter Capacity With Natural Gas | 15 MW |
Net Summer Capacity With Oil | 10 MW |
Net Winter Capacity With Oil | 13 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T8 Details Operating September 2003
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 13 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 12.5 MW |
Winter Capacity | 15 MW |
Minimum Load | 7 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | September 2003 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
---|---|
Topping Or Bottoming | T |
Energy Source | Natural Gas / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Other Combustion Technology | No |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | NG / DFO |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 11 MW |
Net Winter Capacity With Natural Gas | 15 MW |
Net Summer Capacity With Oil | 10 MW |
Net Winter Capacity With Oil | 13 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T12 Details Operating April 2004
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 7 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 7 MW |
Winter Capacity | 7 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | April 2004 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | DFO / NG / BIT |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 7 MW |
Net Winter Capacity With Natural Gas | 7 MW |
Net Summer Capacity With Oil | 7 MW |
Net Winter Capacity With Oil | 7 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T11 Details Operating June 2004
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 12.5 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 12.5 MW |
Winter Capacity | 12.5 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2004 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | DFO / NG / BIT |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 12.5 MW |
Net Winter Capacity With Natural Gas | 12.5 MW |
Net Summer Capacity With Oil | 12.5 MW |
Net Winter Capacity With Oil | 12.5 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator T10 Details Operating August 2004
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 7.8 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 7.8 MW |
Winter Capacity | 7.8 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 2004 |
Combined Heat & Power | Yes |
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
---|---|
Energy Source | Natural Gas / Bituminous Coal / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Stoker Technology | Yes |
Other Combustion Technology | No |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Cofire Energy Source | DFO / NG / BIT |
---|---|
Switch When Operating | Yes |
Net Summer Capacity With Natural Gas | 7.8 MW |
Net Winter Capacity With Natural Gas | 7.8 MW |
Net Summer Capacity With Oil | 7.8 MW |
Net Winter Capacity With Oil | 7.8 MW |
Time To Switch From Gas To Oil | 24H |
Time To Switch From Oil To Gas | 24H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
University of Illinois Abbott Power Plt Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#697 | Richland | Defiance, OH | 231.5 GWh |
#698 | Gramercy Holdings LLC | Gramercy, LA | 231.1 GWh |
#699 | Georgia-Pacific Brewton Mill | Brewton, AL | 490.5 GWh |
#700 | Empire Energy Center | Sarcoxie, MO | 239.0 GWh |
#701 | Manchief Electric Generating Station | Brush, CO | 229.5 GWh |
#702 | Indiana Harbor West | East Chicago, IN | 229.3 GWh |
#703 | El Dorado Refinery | El Dorado, KS | 228.0 GWh |
#704 | Exira | Brayton, IA | 229.8 GWh |
#705 | Angus Anson | Sioux Falls, SD | 232.3 GWh |
#706 | Salinas River Cogeneration | San Ardo, CA | 226.0 GWh |
#708 | University of California San Diego Hybrid | La Jolla, CA | 223.7 GWh |
#709 | Leon Creek | San Antonio, TX | 223.2 GWh |
#710 | Kern River Eastridge Cogen | Bakersfield, CA | 223.0 GWh |
#711 | Mark One Power Station | Angleton, TX | 222.8 GWh |
#712 | University of Michigan | Ann Arbor, MI | 222.0 GWh |
#713 | Gerald Andrus | Greenville, MS | 221.5 GWh |
#714 | Edge Moor | Wilmington, DE | 222.3 GWh |
#715 | Los Esteros Critical Energy Center | San Jose, CA | 218.4 GWh |
#716 | Kimberly Clark-Unit 1,2,3 | New Milford, CT | 217.4 GWh |
#717 | Cornell University Central Heat | Ithaca, NY | 216.7 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding University of Illinois Abbott Power Plt.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Ameresco Danville Solar, LLC | Tilton, IL | 3.6 GWh | 31.3 mi |
California Ridge Wind Energy LLC | Fithian, IL | 738.8 GWh | 20.5 mi |
CED Champaign Solar LLC | Champaign, IL | 2.9 GWh | 3.5 mi |
Farmer City | Farmer City, IL | 36.0 MWh | 23.1 mi |
Gibson City Energy Center LLC | Gibson City, IL | 75.8 GWh | 26.6 mi |
Goose Creek Energy Center | Monticello, IL | 712.0 MWh | 18.9 mi |
Harvest Ridge Wind Farm | Newman, IL | 734.7 GWh | 20.9 mi |
Hoopeston Wind LLC | Rossville, IL | 334.1 GWh | 31 mi |
IL Sidney Project1 | Sidney, IL | 4.2 GWh | 11.6 mi |
Northern Cardinal Solar SCS IL 1, LLC | Champaign, IL | 19.0 GWh | 2.4 mi |
Phoenix Solar South Farms LLC Solar Farm | Champaign, IL | 6.5 GWh | 1.6 mi |
Pioneer Trail Wind Farm, LLC | Paxton, IL | 433.8 GWh | 27.4 mi |
Rantoul | Rantoul, IL | 120.0 MWh | 14.9 mi |
Rantoul Solar | Rantoul, IL | 3.0 GWh | 13.8 mi |
Sapphire Sky Wind Energy LLC | Farmer City, IL | 930.9 GWh | 22.3 mi |
SCS West Fairchild 011958 Danville, LLC | Danville, IL | 2.7 GWh | 31.3 mi |
Solar Star Urbana Landfill Central | Urbana, IL | 3.5 GWh | 3.5 mi |
Solar Star Urbana Landfill East | Urbana, IL | 3.2 GWh | 3.6 mi |
TAC-Distributed Energy Resource Hybrid | Champaign, IL | 266.0 MWh | 1.1 mi |
Tilton | Tilton, IL | 62.7 GWh | 31.1 mi |