University of California Santa Cruz
Heat Plant, UCSC, Santa Cruz, CA 95064Plant Summary Information
University of California Santa Cruz is ranked #125 out of 346 natural gas power plants in California in terms of total annual net electricity generation.
University of California Santa Cruz generated 10.4 GWh during the 3-month period between September 2023 to December 2023.
Plant Name | University of California Santa Cruz |
---|---|
Utility Name | University of California Santa Cruz |
Location | Santa Cruz County, CA |
Initial Operation Date | September 2013 |
Last Update | Dec 2023 |
Annual Generation | 35.9 GWh |
Annual Consumption | 417.0 k MMBtu |
Ranked #4,307 out of 11,852 Power Plants Nationwide | |
Ranked #1,257 out of 2,254 Natural Gas Power Plants Nationwide | |
Ranked #565 out of 1,570 California Power Plants | |
Ranked #125 out of 346 California Natural Gas Power Plants | |
Fuel Types | Natural Gas : 90.8% Solar : 9.2% |
Previous Operator |
Santa Cruz Cogeneration Assoc (2013 to 2022) University of California Santa Cruz (2023 to 2023) |
Map of University of California Santa Cruz
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for University of California Santa Cruz.
Monthly Net Generation for University of California Santa Cruz
University of California Santa Cruz Details
Summary Information | |
---|---|
Plant Name | University of California Santa Cruz (50064) |
Plant Address | Heat Plant, UCSC, Santa Cruz, CA 95064 |
Utility | University of California Santa Cruz (22142) |
Latitude, Longitude | 36.9997, -122.0622 |
Generation Dates on File | Jan 2001 to Dec 2023 |
Initial Operation Date | September 2013 |
Annual Generation | 35.9 GWh |
Fuel Types | Natural Gas : 90.8% Solar : 9.2% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | Yes |
FERC Cogeneration Docket Number | 84-362-000; 86-937-000 |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | WECC |
Balancing Authority | California Independent System Operator (CISO) |
NAICS Code | Educational Services (611) |
Sector | Commercial CHP (5) |
Water Source | Municipality |
Ash Impoundment | No |
Transmission / Distribution Owner | Pacific Gas & Electric Co (14328) CA |
Grid Voltage | 21.00 kV |
Energy Storage | Yes |
Natural Gas Information | |
Pipeline Name | PACIFIC GAS |
Natural Gas Storage | No |
Liquefied Natural Gas Storage | No |
Generator 004 Details Operating September 2013
Technology | Solar Photovoltaic |
---|---|
Prime Mover | Photovoltaic |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 0.2 MW |
Summer Capacity | 0.2 MW |
Winter Capacity | 0.1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | September 2013 |
---|---|
Combined Heat & Power | No |
Sector Name | Commercial CHP (5) |
Energy Source | Solar |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Solar Details | |
Fixed Tilt | Yes |
---|---|
Azimuth Angle | 200 |
Tilt Angle | 5 |
DC Net Capacity | 0.3 MW |
Crystalline Silicon | Yes |
Net Metering Agreement | Yes |
Net Metering DC Capacity | 0.3 MW |
Virtual Net Metering Agreement | No |
Generator 003 Details Operating July 2015
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 4.4 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 4.4 MW |
Winter Capacity | 4.4 MW |
Minimum Load | 0.5 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 2015 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator 246 Details Operating July 2021
Technology | Solar Photovoltaic |
---|---|
Prime Mover | Photovoltaic |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 1.8 MW |
Summer Capacity | 1.8 MW |
Winter Capacity | 1.8 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 2021 |
---|---|
Combined Heat & Power | No |
Sector Name | Commercial CHP (5) |
Energy Source | Solar |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Solar Details | |
Single Axis Tracking | No |
---|---|
Fixed Tilt | Yes |
Azimuth Angle | 200 |
Tilt Angle | 7 |
DC Net Capacity | 2.2 MW |
Crystalline Silicon | Yes |
Net Metering Agreement | Yes |
Net Metering DC Capacity | 2.2 MW |
Virtual Net Metering Agreement | No |
Generator 18027 Details Operating December 2022
Technology | Batteries |
---|---|
Prime Mover | Battery |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 1 MW |
Summer Capacity | 1 MW |
Winter Capacity | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | December 2022 |
---|---|
Combined Heat & Power | No |
Sector Name | Commercial CHP (5) |
Energy Source | Electricity used for energy storage |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Energy Storage Details | |
Nameplate Energy Capacity MWH | 1 |
---|---|
Maximum Charge Rate | 1 MW |
Maximum Discharge Rate | 1 MW |
Storage Technology | LIB |
Storage Enclosure Type | CS |
Co Located Renewable Firming | Yes |
System Peak Shaving | P |
Excess Wind And Solar Generation | Yes |
Ac Coupled | Yes |
Direct Support Of Another Unit | Yes |
Direct Support Plant Id | 50064 |
Direct Support Gen Id | 246 |
Support T D Asset | No |
University of California Santa Cruz Plant Owners
Owner Name | Address | Generator | Ownership |
---|---|---|---|
EDPR CA Solar Park LLC | 1501 McKinney Street, Suite 1300, Houston, TX 77010 | Generator 004 | 100.00% |
Forefront Power, LLC | 100 Montgomery Street, Suite 725, San Francisco, CA 94104 | Generator 18027 | 100.00% |
Forefront Power, LLC | 100 Montgomery Street, Suite 725, San Francisco, CA 94104 | Generator 246 | 100.00% |
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1247 | Longview Fibre | Longview, WA | 170.9 GWh |
#1248 | Pittsfield Generating LP | Pittsfield, MA | 33.7 GWh |
#1249 | Cutrale Citrus Juices USA II | Auburndale, FL | 33.4 GWh |
#1250 | Georgia-Pacific Big Island | Big Island, VA | 53.7 GWh |
#1251 | Lon Wright | Fremont, NE | 521.6 GWh |
#1252 | International Paper Co. - New Bern Mill | New Bern, NC | 197.8 GWh |
#1253 | Kaiser - LA | Los Angeles, CA | 33.1 GWh |
#1254 | W Plant | San Diego, CA | 32.9 GWh |
#1255 | Newgulf Cogen | NewGulf, TX | 32.9 GWh |
#1256 | Somerset Plant | Skowhegan, ME | 495.5 GWh |
#1258 | University of Rochester | Rochester, NY | 32.5 GWh |
#1259 | Radford Army Ammunition Plant | Radford, VA | 32.2 GWh |
#1260 | Great Bend - Sunflower | Great Bend, KS | 32.0 GWh |
#1261 | Village Creek Water Reclamation Facility | Arlington, TX | 31.9 GWh |
#1262 | Ray D Nixon | Fountain, CO | 930.7 GWh |
#1263 | Valmont Combustion Turbine Project | Boulder, CO | 31.7 GWh |
#1264 | Sun Peak Generating Station | Las Vegas, NV | 31.6 GWh |
#1265 | Eastern Maine Medical Center | Bangor, ME | 31.6 GWh |
#1266 | North 1st | Brooklyn, NY | 31.5 GWh |
#1267 | Central Energy Plant USU | Logan, UT | 31.4 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding University of California Santa Cruz.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
AGT000 Stevens Creek Fuel Cell | Santa Clara, CA | 6.3 GWh | 22.7 mi |
Ameresco Santa Cruz Energy | Watsonville, CA | 18.8 GWh | 14.7 mi |
APP Prune A-D | Cupertino, CA | 27.1 GWh | 23.1 mi |
Apple Campus 2 Fuel Cell | Cupertino, CA | 25.9 GWh | 23 mi |
Apple Campus 2 PV | Cupertino, CA | 15.6 GWh | 23 mi |
Cabrillo College | Aptos, CA | 13.0 MWh | 7.8 mi |
Dynegy Moss Landing Power Plant Hybrid | Moss Landing, CA | 4.5 TWh | 20.5 mi |
Equinix Great Oaks Blvd. Fuel Cell | San Jose, CA | 28.2 GWh | 22.7 mi |
Equinix San Jose | San Jose, CA | 7.6 GWh | 22.8 mi |
EQX010 Great Oaks Fuel Cell | San Jose, CA | 16.5 GWh | 22.7 mi |
EQX015 Great Oaks Fuel Cell | San Jose, CA | 29.2 GWh | 22.8 mi |
Extreme San Ignacio | San Jose, CA | 6.0 GWh | 22.4 mi |
Extreme Via Del Oro | San Jose, CA | 8.5 GWh | 22.5 mi |
Gap Pacific Distribution Center | Fresno, CA | 5.7 GWh | 20.8 mi |
Guadalupe Solar Farm | San Jose, CA | 2.3 GWh | 21.7 mi |
Malech Solar Farm | San Jose, CA | 5.3 GWh | 23.8 mi |
Metcalf Energy Center | San Jose, CA | 2.9 TWh | 23.2 mi |
Santa Cruz Energy | Santa Cruz, CA | 10.0 GWh | 3 mi |
UC Santa Cruz Solar | Santa Cruz, CA | 3.5 GWh | 0.8 mi |