Turkey Point
9700 SW 344th Street, Homestead, FL 33035Plant Summary Information
Turkey Point is ranked #6 out of 11,852 power plants nationwide in terms of total annual net electricity generation.
Turkey Point is comprised of 7 generators and generated 5.9 TWh during the 3-month period between June 2024 to September 2024.
Plant Name | Turkey Point |
---|---|
Utility Name | Florida Power & Light Co |
Location | Miami-Dade County, FL |
Initial Operation Date | April 1967 |
Last Update | Sep 2024 |
Annual Generation | 21.4 TWh |
Annual Consumption | 215.9 M MMBtu |
Ranked #6 out of 11,852 Power Plants Nationwide | |
Ranked #30 out of 54 Nuclear Power Plants Nationwide | |
Ranked #1 out of 279 Florida Power Plants | |
Ranked #2 out of 2 Florida Nuclear Power Plants | |
Fuel Types | Nuclear : 66.9% Natural Gas : 33.1% |
Map of Turkey Point
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Turkey Point.
Monthly Net Generation for Turkey Point
Turkey Point Details
Summary Information | |
---|---|
Plant Name | Turkey Point (621) |
Plant Address | 9700 SW 344th Street, Homestead, FL 33035 |
Utility | Florida Power & Light Co (6452) |
Latitude, Longitude | 25.4356, -80.3308 |
Generation Dates on File | Jan 2001 to Sep 2024 |
Initial Operation Date | April 1967 |
Annual Generation | 21.4 TWh |
Fuel Types | Nuclear : 66.9% Natural Gas : 33.1% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | SERC |
Balancing Authority | Florida Power & Light Company (FPL) |
NAICS Code | Utilities (22) |
Sector | Electric Utility (1) |
Water Source | Biscayne Bay |
Ash Impoundment | |
Transmission / Distribution Owner | Florida Power & Light Co (6452) FL |
Grid Voltage | 230.00 kV |
Energy Storage | No |
Natural Gas Information | |
Pipeline Name | FLORIDA GAS TRANSMISSION COMPANY |
Natural Gas Storage | No |
Generator 3 Details Operating December 1972
Technology | Nuclear |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 877.2 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 837 MW |
Winter Capacity | 859 MW |
Minimum Load | 420 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | December 1972 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Nuclear |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | OVER |
Multiple Fuels | No |
Generator 4 Details Operating September 1973
Technology | Nuclear |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 760 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 861 MW |
Winter Capacity | 888 MW |
Minimum Load | 424 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | September 1973 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Nuclear |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | OVER |
Multiple Fuels | No |
Generator 5CA Details Operating May 2007
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Steam Part |
Unit Code | G901 |
Ownership | Single Owner |
Duct Burners | No |
Nameplate Capacity | 472 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 466.2 MW |
Winter Capacity | 460 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2007 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 451 MW |
Net Winter Capacity With Natural Gas | 460 MW |
Net Summer Capacity With Oil | 333 MW |
Net Winter Capacity With Oil | 359 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 5CTA Details Operating May 2007
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | G901 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
Nameplate Capacity | 188 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 197.8 MW |
Winter Capacity | 207 MW |
Minimum Load | 90 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2007 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 160 MW |
Net Winter Capacity With Natural Gas | 207 MW |
Net Summer Capacity With Oil | 165 MW |
Net Winter Capacity With Oil | 178 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 5CTB Details Operating May 2007
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | G901 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
Nameplate Capacity | 188 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 196.7 MW |
Winter Capacity | 207 MW |
Minimum Load | 90 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2007 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 160 MW |
Net Winter Capacity With Natural Gas | 207 MW |
Net Summer Capacity With Oil | 165 MW |
Net Winter Capacity With Oil | 178 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 5CTC Details Operating May 2007
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | G901 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
Nameplate Capacity | 188 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 196.7 MW |
Winter Capacity | 207 MW |
Minimum Load | 90 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2007 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 160 MW |
Net Winter Capacity With Natural Gas | 207 MW |
Net Summer Capacity With Oil | 165 MW |
Net Winter Capacity With Oil | 178 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 5CTD Details Operating May 2007
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | G901 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
Nameplate Capacity | 188 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 196.7 MW |
Winter Capacity | 207 MW |
Minimum Load | 90 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2007 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 160 MW |
Net Winter Capacity With Natural Gas | 207 MW |
Net Summer Capacity With Oil | 165 MW |
Net Winter Capacity With Oil | 178 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Turkey Point Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Nuclear.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#20 | Millstone | Waterford, CT | 16.0 TWh |
#21 | Brunswick Nuclear | Southport, NC | 15.9 TWh |
#22 | Arkansas Nuclear One | Russellville, AR | 15.5 TWh |
#23 | Nine Mile Point Nuclear Station | Lycoming, NY | 15.5 TWh |
#24 | Quad Cities Generating Station | Cordova, IL | 15.5 TWh |
#25 | North Anna | Mineral, VA | 15.4 TWh |
#26 | Dresden Generating Station | Morris, IL | 15.3 TWh |
#27 | Beaver Valley | Shippingport, PA | 15.2 TWh |
#28 | St Lucie | Jensen Beach, FL | 15.0 TWh |
#29 | Calvert Cliffs Nuclear Power Plant | Lusby, MD | 14.8 TWh |
#31 | Joseph M Farley | Columbia, AL | 14.2 TWh |
#32 | Edwin I Hatch | Baxley, GA | 14.1 TWh |
#33 | Surry | Surry, VA | 13.8 TWh |
#34 | Seabrook | Seabrook, NH | 10.9 TWh |
#35 | Perry | Perry, OH | 10.7 TWh |
#36 | Grand Gulf | Port Gibson, MS | 10.6 TWh |
#37 | Point Beach Nuclear Plant | Two Rivers, WI | 10.1 TWh |
#38 | Columbia Generating Station | Richland, WA | 9.9 TWh |
#39 | Callaway | Fulton, MO | 9.4 TWh |
#40 | Clinton Power Station | Clinton, IL | 9.3 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Turkey Point.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Beautyberry | Clewiston, FL | 134.4 GWh | 77.2 mi |
CSL Gas Recovery | Pompano Beach, FL | 40.0 GWh | 59.8 mi |
Dania Beach 7 | Ft. Lauderdale, FL | 6.6 TWh | 44.5 mi |
Everglades Solar Energy Center | Homestead, FL | 141.7 GWh | 15.8 mi |
FIU Solar | Miami, FL | 1.5 GWh | 23.2 mi |
Ghost Orchid Solar Energy Center | Clewiston, FL | 136.3 GWh | 80.7 mi |
Hibiscus Solar Energy Center | Westlake, FL | 145.9 GWh | 91.5 mi |
IKEA Miami 327 | Miami, FL | 1.4 GWh | 24.8 mi |
Lauderdale | Ft. Lauderdale, FL | 262.3 GWh | 44.5 mi |
Miami Dade County Resource Recovery Fac | Miami, FL | 233.7 GWh | 27.7 mi |
Miami Dade Solar Energy Center | Miami, FL | 129.7 GWh | 17.3 mi |
Okeelanta Cogeneration | South Bay, FL | 40.5 GWh | 83 mi |
Pembroke Lakes Mall | Pembroke Pines, FL | 596.0 MWh | 39.8 mi |
Port Everglades | Ft. Lauderdale, FL | 5.2 TWh | 46.7 mi |
Sawgrass Solar Energy Center | Clewiston, FL | 138.4 GWh | 79.3 mi |
South District Wastewater Treatment Plt | Miami, FL | 22.6 GWh | 7.9 mi |
Tom G Smith | Lake Worth, FL | 444.0 MWh | 83 mi |
West County Energy Center | Loxahatchee, FL | 21.0 TWh | 87.3 mi |
Wheelabrator South Broward | Ft. Lauderdale, FL | 414.3 GWh | 44.5 mi |
Woodyard | Clewiston, FL | 102.7 GWh | 80.7 mi |