Troy Energy LLC
22379 Pemberville Road, Luckey, OH 43443Plant Summary Information
Troy Energy LLC is ranked #22 out of 170 power plants in Ohio in terms of total annual net electricity generation.
Troy Energy LLC is comprised of 4 generators and generated 348.8 GWh during the 3-month period between September 2022 to December 2022.
Plant Name | Troy Energy LLC |
---|---|
Utility Name | Troy Energy LLC |
Location | Wood County, OH |
Initial Operation Date | June 2002 |
Last Update | Dec 2022 |
Annual Generation | 1.1 TWh |
Annual Consumption | 14.0 M MMBtu |
Ranked #737 out of 11,249 Power Plants Nationwide | |
Ranked #449 out of 2,188 Natural Gas Power Plants Nationwide | |
Ranked #22 out of 170 Ohio Power Plants | |
Ranked #15 out of 52 Ohio Natural Gas Power Plants | |
Fuel Types | Natural Gas : 81.9% Distillate Fuel Oil : 18.1% |
Map of Troy Energy LLC
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Troy Energy LLC.
Monthly Net Generation for Troy Energy LLC
Troy Energy LLC Details
Summary Information | |
---|---|
Plant Name | Troy Energy LLC (55348) |
Plant Address | 22379 Pemberville Road Luckey, OH 43443 |
Utility | Troy Energy LLC (56533) |
Latitude, Longitude | 41.47724, -83.45983 |
Generation Dates on File | Jul 2002 to Dec 2022 |
Initial Operation Date | June 2002 |
Annual Generation | 1.1 TWh |
Fuel Types | Natural Gas : 81.9% Distillate Fuel Oil : 18.1% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | Yes |
FERC Exempt Wholesale Generator Docket Number | 00-28-000 |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | RFC |
Balancing Authority | PJM Interconnection, LLC (PJM) |
NAICS Code | Utilities (22) |
Sector | IPP Non-CHP (2) |
Water Source | |
Ash Impoundment | No |
Transmission / Distribution Owner | American Transmission Systems Inc (56162) |
Grid Voltage | 345.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | EAST OHIO GAS COMP DOMINION EAST OH |
Pipeline Name | DOMINION TRANSMISSION INCORPORATED |
Natural Gas Storage | No |
Generator 1 Details Operating June 2002
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 198.9 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 170 MW |
Winter Capacity | 196.6 MW |
Minimum Load | 100 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2002 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 157 MW |
Net Winter Capacity With Natural Gas | 196 MW |
Net Summer Capacity With Oil | 176.9 MW |
Net Winter Capacity With Oil | 198 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 2 Details Operating June 2002
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 198.9 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 169 MW |
Winter Capacity | 196.5 MW |
Minimum Load | 100 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2002 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 157 MW |
Net Winter Capacity With Natural Gas | 196 MW |
Net Summer Capacity With Oil | 174.2 MW |
Net Winter Capacity With Oil | 198 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 3 Details Operating June 2002
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 198.9 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 168.5 MW |
Winter Capacity | 196.6 MW |
Minimum Load | 100 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2002 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 157 MW |
Net Winter Capacity With Natural Gas | 196 MW |
Net Summer Capacity With Oil | 174.2 MW |
Net Winter Capacity With Oil | 198 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 4 Details Operating June 2002
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 198.9 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 168.1 MW |
Winter Capacity | 196 MW |
Minimum Load | 100 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2002 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 157 MW |
Net Winter Capacity With Natural Gas | 196 MW |
Net Summer Capacity With Oil | 176 MW |
Net Winter Capacity With Oil | 198 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Troy Energy LLC Plant Owners
Owner Name | Address | Generator | Ownership |
---|---|---|---|
LS Power Development LLC | 400 Chesterfield Center,Suite 110, St. Louis, MO 63017 | Generator 1 | 100.00% |
LS Power Development LLC | 400 Chesterfield Center,Suite 110, St. Louis, MO 63017 | Generator 2 | 100.00% |
LS Power Development LLC | 400 Chesterfield Center,Suite 110, St. Louis, MO 63017 | Generator 3 | 100.00% |
LS Power Development LLC | 400 Chesterfield Center,Suite 110, St. Louis, MO 63017 | Generator 4 | 100.00% |
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#439 | Black Dog | Burnsville, MN | 939.2 GWh |
#440 | CFB Power Plant | Point Comfort, TX | 930.1 GWh |
#441 | Washington County Cogeneration Facility | McIntosh, AL | 920.8 GWh |
#442 | Procter & Gamble Mehoopany Mill | Mehoopany, PA | 913.9 GWh |
#443 | McMeekin | Columbia, SC | 899.3 GWh |
#444 | Garrison Energy Center LLC | Dover, DE | 899.7 GWh |
#445 | Panoche Energy Center | Firebaugh, CA | 896.9 GWh |
#446 | EG178 Facility | Snyder, TX | 893.9 GWh |
#447 | Holland Energy Park | Holland, MI | 881.1 GWh |
#448 | Sim Gideon | Bastrop, TX | 860.1 GWh |
#450 | Ladysmith | Woodford, VA | 879.5 GWh |
#451 | Power Island | Alvin, TX | 837.6 GWh |
#452 | McIntosh (AL) | McIntosh, AL | 834.6 GWh |
#453 | Deer Creek Station | White, SD | 826.3 GWh |
#454 | Southwestern | Anadarko, OK | 825.2 GWh |
#455 | Newington | Newington, NH | 824.8 GWh |
#456 | Mustang Station Unit 4 | Denver City, TX | 822.5 GWh |
#457 | Rockingham County CT Station | Reidsville, NC | 834.6 GWh |
#458 | Hardee Power Station | Bowling Green, FL | 817.3 GWh |
#459 | Topaz Generating | Texas City, TX | 814.4 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Troy Energy LLC.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Anthony Wayne Solar #1 | Toledo, OH | 1.7 GWh | 11.9 mi |
Bay View Backup Power Facility | Toledo, OH | 162.3 MWh | 14.6 mi |
Bowling Green Generating Station | Bowling Green, OH | 1.7 GWh | 10.9 mi |
Bowling Green Wind | Bowling Green, OH | 5.9 GWh | 16 mi |
Clyde Solar Array | Clyde, OH | 4.2 GWh | 27 mi |
Davis Besse | Oak Harbor, OH | 8.1 TWh | 21 mi |
DG AMP Solar Bowling Green | Bowling Green, OH | 41.8 GWh | 8.5 mi |
Findlay Wind Farm | Findlay, OH | 9.2 GWh | 27.7 mi |
FirstEnergy Bay Shore | Oregon, OH | 995.5 GWh | 14.9 mi |
Fremont Energy Center | Fremont, OH | 3.8 TWh | 16.9 mi |
Genoa Diesel Generating Station | Genoa, OH | 146.3 MWh | 5.6 mi |
Oregon Clean Energy Center | Oregon, OH | 7.1 TWh | 13.2 mi |
Owens Corning Headquarters | Toledo, OH | 1.6 GWh | 12.2 mi |
PNA Rossford Solar Array | Rossford, OH | 1.3 GWh | 10.8 mi |
POET Biorefining - Fostoria | Fostoria, OH | 20.2 GWh | 21.5 mi |
Temperance Solar, LLC | Erie, MI | 42.1 GWh | 19.3 mi |
Toledo Ref Power Recovery Train | Oregon, OH | 1.4 GWh | 11 mi |
Woodville RTO BTM | Woodville, OH | 29.0 MWh | 4.9 mi |
Zephyr Wind | Findlay, OH | 13.2 GWh | 28 mi |
Zephyr Wind Project - 2.0 | Findlay, OH | 13.3 GWh | 28.1 mi |