Terry Bundy Generating Station
7707 Bluff Road, Lincoln, NE 68517Plant Summary Information
Terry Bundy Generating Station is ranked #36 out of 116 power plants in Nebraska in terms of total annual net electricity generation.
Terry Bundy Generating Station is comprised of 8 generators and generated 67.8 GWh during the 3-month period between May 2024 to August 2024.
Plant Name | Terry Bundy Generating Station |
---|---|
Utility Name | Lincoln Electric System |
Location | Lancaster County, NE |
Initial Operation Date | August 2003 |
Last Update | Aug 2024 |
Annual Generation | 118.5 GWh |
Annual Consumption | 1.4 M MMBtu |
Ranked #2,973 out of 11,835 Power Plants Nationwide | |
Ranked #916 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #36 out of 116 Nebraska Power Plants | |
Ranked #5 out of 33 Nebraska Natural Gas Power Plants | |
Fuel Types | Natural Gas : 79.9% Landfill Gas : 17.9% Distillate Fuel Oil : 2.2% |
Map of Terry Bundy Generating Station
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Terry Bundy Generating Station.
Monthly Net Generation for Terry Bundy Generating Station
Terry Bundy Generating Station Details
Summary Information | |
---|---|
Plant Name | Terry Bundy Generating Station (7887) |
Plant Address | 7707 Bluff Road, Lincoln, NE 68517 |
Utility | Lincoln Electric System (11018) |
Latitude, Longitude | 40.90965, -96.61309 |
Generation Dates on File | Jan 2004 to Aug 2024 |
Initial Operation Date | August 2003 |
Annual Generation | 118.5 GWh |
Fuel Types | Natural Gas : 79.9% Landfill Gas : 17.9% Distillate Fuel Oil : 2.2% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | MRO |
Balancing Authority | Southwest Power Pool (SWPP) |
NAICS Code | Utilities (22) |
Sector | Electric Utility (1) |
Water Source | Effluent |
Ash Impoundment | No |
Transmission / Distribution Owner | Lincoln Electric System (11018) NE |
Grid Voltage | 115.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | Other - See pipeline notes. |
Pipeline Name | NORTHERN NATURAL GAS |
Natural Gas Storage | No |
Generator 2 Details Operating October 2003
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | CC1 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | Yes |
RTO ISO LMP Node Designation | LES84_BLUFPLT1 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_TBGS_CC1 |
Nameplate Capacity | 60.5 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 46 MW |
Winter Capacity | 48 MW |
Minimum Load | 20 MW |
Uprate/Derate Completed | No |
---|---|
Status | Operating |
First Operation Date | October 2003 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 47 MW |
Net Winter Capacity With Natural Gas | 48 MW |
Net Summer Capacity With Oil | 45 MW |
Net Winter Capacity With Oil | 46 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator 4 Details Operating August 2003
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LES84_BLUFUNSALT_VALLEY_4_RA__ |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_TBGS_CT4 |
Nameplate Capacity | 60.5 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 45.4 MW |
Winter Capacity | 48 MW |
Minimum Load | 20 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | August 2003 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 47 MW |
Net Winter Capacity With Natural Gas | 48 MW |
Net Summer Capacity With Oil | 45 MW |
Net Winter Capacity With Oil | 46 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | No |
Generator 3 Details Operating April 2004
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | CC1 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | Yes |
RTO ISO LMP Node Designation | LES84_BLUFPLT1 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_TBGS_CC1 |
Nameplate Capacity | 60.5 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 45.2 MW |
Winter Capacity | 48 MW |
Minimum Load | 20 MW |
Uprate/Derate Completed | No |
---|---|
Status | Operating |
First Operation Date | April 2004 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 47 MW |
Net Winter Capacity With Natural Gas | 48 MW |
Net Summer Capacity With Oil | 45 MW |
Net Winter Capacity With Oil | 46 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | No |
Generator BSU Details Operating July 2004
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 1.8 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.6 MW |
Winter Capacity | 1.6 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 2004 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator 1 Details Operating August 2004
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Steam Part |
Unit Code | CC1 |
Ownership | Single Owner |
Duct Burners | Yes |
RTO ISO LMP Node Designation | LES84_BLUFPLT1 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_TBGS_CC1 |
Nameplate Capacity | 28.2 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 27.3 MW |
Winter Capacity | 28.6 MW |
Minimum Load | 10 MW |
Uprate/Derate Completed | No |
---|---|
Status | Operating |
First Operation Date | August 2004 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Subcritical Technology | Yes |
Multiple Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator LFG1 Details Operating January 2014
Technology | Landfill Gas |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LES84_BLUFUNTBGS_LFG_G1_RA |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_LFG_1 |
Nameplate Capacity | 1.6 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.6 MW |
Winter Capacity | 1.6 MW |
Minimum Load | 1.1 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | January 2014 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Landfill Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator LFG2 Details Operating January 2014
Technology | Landfill Gas |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LES84_BLUFUNTBGS_LFG_G1_RA |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_LFG_1 |
Nameplate Capacity | 1.6 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.6 MW |
Winter Capacity | 1.6 MW |
Minimum Load | 1.1 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | January 2014 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Landfill Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator LFG3 Details Operating January 2014
Technology | Landfill Gas |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LES84_BLUFUNTBGS_LFG_G1_RA |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_LFG_1 |
Nameplate Capacity | 1.6 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.6 MW |
Winter Capacity | 1.6 MW |
Minimum Load | 1.1 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | January 2014 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Landfill Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Switch Between Oil And Natural Gas | No |
Terry Bundy Generating Station Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#906 | PCA, Filer City Mill | Filer City, MI | 97.3 GWh |
#907 | Edgewood Energy LLC | Brentwood, NY | 97.3 GWh |
#908 | Nearman Creek | Kansas, KS | 646.5 GWh |
#909 | Bob Glanzer Generating Station | Huron, SD | 96.4 GWh |
#910 | Mont Belvieu Cogeneration Unit | Mont Belvieu, TX | 96.3 GWh |
#911 | McCartney | Strafford, MO | 96.1 GWh |
#912 | Lockport Energy Associates LP | Lockport, NY | 96.0 GWh |
#913 | Southeast Kern River Cogen | Bakersfield, CA | 95.7 GWh |
#914 | DeBary | DeBary, FL | 105.5 GWh |
#915 | Black Mountain Generating Station | Golden Valley, AZ | 94.9 GWh |
#917 | Vanderbilt University Power Plant | Nashville, TN | 94.3 GWh |
#918 | West Marinette | Peshtigo, WI | 93.8 GWh |
#919 | CML&P Generating Facility No. 2 | Coffeyville, KS | 93.2 GWh |
#920 | Mariposa Energy Project | Byron, CA | 92.8 GWh |
#921 | Oak Point Cogen | Belle Chasse, LA | 92.8 GWh |
#922 | Harlem River Yard | Bronx, NY | 92.5 GWh |
#923 | Greens Bayou | Houston, TX | 92.3 GWh |
#924 | University of Notre Dame | Notre Dame, IN | 92.2 GWh |
#925 | Pixelle Specialty Solutions LLC - Spring Grove Facility | Spring Grove, PA | 387.5 GWh |
#926 | Bellingham Cogeneration Facility | Bellingham, MA | 102.2 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Terry Bundy Generating Station.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Archer Daniels Midland Lincoln | Lincoln, NE | 9.0 GWh | 3 mi |
Beatrice | Beatrice, NE | 579.6 GWh | 41.3 mi |
Cass County | Plattsmouth, NE | 210.4 GWh | 34 mi |
Crete | Crete, NE | 83.0 MWh | 26.8 mi |
David City | David City, NE | 8.0 MWh | 35.5 mi |
Elk City Station | Bennington, NE | 48.7 GWh | 37.7 mi |
Hallam | Hallam, NE | 2.4 GWh | 25.9 mi |
Holdrege Solar Center | Lincoln, NE | 6.5 GWh | 12.3 mi |
J Street | Lincoln, NE | 4.5 GWh | 8.7 mi |
Lon Wright | Fremont, NE | 521.6 GWh | 36.7 mi |
Missouri River Wastewater Treatment | Omaha, NE | 12.8 GWh | 41 mi |
Papillion Creek Wastewater | Bellevue, NE | 6.6 GWh | 40.4 mi |
Platteview Solar LLC | Ashland, NE | 66.7 GWh | 22.9 mi |
Rokeby | Lincoln, NE | 80.3 GWh | 13.9 mi |
Salt Valley Wind Plant | Lincoln, NE | 2.0 GWh | 0.6 mi |
Sarpy County | Bellevue, NE | 161.8 GWh | 38 mi |
Seward Wind Farm | Seward, NE | 7.0 GWh | 30.4 mi |
Sheldon | Hallam, NE | 612.1 GWh | 25.8 mi |
Wahoo | Wahoo, NE | 58.0 MWh | 20.9 mi |
Wilber | Wilber, NE | 33.0 MWh | 34.8 mi |