TalenEnergy Montour
18 McMichael Road, Washingtonville, PA 17884Plant Summary Information
TalenEnergy Montour is ranked #30 out of 231 power plants in Pennsylvania in terms of total annual net electricity generation.
TalenEnergy Montour is comprised of 2 generators and generated 1.5 TWh during the 3-month period between May 2024 to August 2024.
Plant Name | TalenEnergy Montour |
---|---|
Utility Name | TalenEnergy Montour LLC |
Location | Montour County, PA |
Initial Operation Date | February 1971 |
Last Update | Aug 2024 |
Annual Generation | 2.4 TWh |
Annual Consumption | 25.5 M MMBtu |
Ranked #471 out of 11,835 Power Plants Nationwide | |
Ranked #328 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #30 out of 231 Pennsylvania Power Plants | |
Ranked #23 out of 78 Pennsylvania Natural Gas Power Plants | |
Fuel Types | Natural Gas : 81.0% Bituminous Coal : 18.9% |
Previous Operator |
PPL Montour LLC (2013 to 2014) TalenEnergy Montour LLC (2015 to 2023) |
Map of TalenEnergy Montour
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for TalenEnergy Montour.
Monthly Net Generation for TalenEnergy Montour
TalenEnergy Montour Details
Summary Information | |
---|---|
Plant Name | TalenEnergy Montour (3149) |
Plant Address | 18 McMichael Road, Washingtonville, PA 17884 |
Utility | TalenEnergy Montour LLC (15534) |
Latitude, Longitude | 41.0714, -76.6672 |
Generation Dates on File | Jan 2001 to Aug 2024 |
Initial Operation Date | February 1971 |
Annual Generation | 2.4 TWh |
Fuel Types | Natural Gas : 81.0% Bituminous Coal : 18.9% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | Yes |
FERC Exempt Wholesale Generator Docket Number | 00-44-000; 01-36-000 ; 01-43-000 |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | RFC |
Balancing Authority | PJM Interconnection, LLC (PJM) |
NAICS Code | Utilities (22) |
Sector | IPP Non-CHP (2) |
Water Source | Susquehanna River |
Ash Impoundment | Yes Not Lined Operating |
Transmission / Distribution Owner | PPL Electric Utilities Corp (14715) PA |
Grid Voltage | 230.00 kV |
Energy Storage | No |
Natural Gas Information | |
Pipeline Name | Other - Please explain in pipeline notes below. |
Pipeline Notes | Talen owns the lateral gas pipeline that connects to the facility. At the other end, the lateral is connected to the Stagecoach gas pipeline. The gas is contracted to be supplied by |
Natural Gas Storage | No |
Generator 1 Details Operating March 1972
Technology | Conventional Steam Coal |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | 50628 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | 50628 |
Nameplate Capacity | 864.9 MW |
Nameplate Power Factor | 0.93 |
Summer Capacity | 752 MW |
Winter Capacity | 752 MW |
Minimum Load | 338 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | March 1972 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Bituminous Coal / Natural Gas |
Startup Source | Distillate Fuel Oil / Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | OVER |
Pulverized Coal Technology | Yes |
Supercritical Technology | Yes |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | BIT / DFO / NG |
---|
Generator 2 Details Operating April 1973
Technology | Natural Gas Steam Turbine |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | 50629 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | 50629 |
Nameplate Capacity | 893 MW |
Nameplate Power Factor | 0.94 |
Summer Capacity | 752 MW |
Winter Capacity | 752 MW |
Minimum Load | 342 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | April 1973 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Bituminous Coal |
Startup Source | Distillate Fuel Oil / Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | OVER |
Pulverized Coal Technology | Yes |
Supercritical Technology | Yes |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | BIT / DFO / NG |
---|
TalenEnergy Montour Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#318 | Hidalgo Energy Center | Edinburg, TX | 2.1 TWh |
#319 | Bayou Cogen Plant | Pasadena, TX | 2.3 TWh |
#320 | Coyote Springs | Boardman, OR | 2.0 TWh |
#321 | Midulla Generating Station | Bowling Green, FL | 2.0 TWh |
#322 | Moselle | Moselle, MS | 2.0 TWh |
#323 | Mint Farm Generating Station | Longview, WA | 2.0 TWh |
#324 | Frontera Energy Center | Mission, TX | 2.0 TWh |
#325 | Watson Cogeneration | Carson, CA | 2.4 TWh |
#326 | Apache Station | Cochise, AZ | 2.2 TWh |
#327 | St Francis Energy Facility | Campbell, MO | 2.0 TWh |
#329 | O W Sommers | San Antonio, TX | 1.9 TWh |
#330 | Cedar Bayou 4 | Eldon, TX | 1.9 TWh |
#331 | Jackson Generating Station | Jackson, MI | 1.9 TWh |
#332 | Sutter Energy Center | Yuba City, CA | 1.9 TWh |
#333 | Langley Gulch Power Plant | New Plymouth, ID | 1.9 TWh |
#334 | Treasure Coast Energy Center | Ft. Pierce, FL | 1.8 TWh |
#335 | Sweeny Cogen Facility | Old Ocean, TX | 2.5 TWh |
#336 | Frederickson Power LP | Tacoma, WA | 1.8 TWh |
#337 | Shawville | Shawville, PA | 1.8 TWh |
#338 | Rathdrum Power LLC | Rathdrum, ID | 1.8 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding TalenEnergy Montour.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Allenwood | Montgomery, PA | 22.5 GWh | 14.2 mi |
Broad Mountain | Schuylkill, PA | 38.0 GWh | 31.5 mi |
Bucknell University | Lewisburg, PA | 41.7 GWh | 13.7 mi |
ER Bison Solar CSG | Lewisburg, PA | 2.2 GWh | 14.8 mi |
Foster Wheeler Mt Carmel Cogen | Marion Heights, PA | 103.7 GWh | 21.2 mi |
Hamilton Patriot Generation Plant | Montgomery, PA | 6.4 TWh | 11.7 mi |
Hummel Station LLC | Shamokin Dam, PA | 8.4 TWh | 18.1 mi |
Hunlock Power Station | Hunlok Creek, PA | 603.0 GWh | 32.3 mi |
Hunlock Unit 4 | Hunlock Green, PA | 50.3 GWh | 32.5 mi |
John B Rich Memorial Power Station | Frackville, PA | 624.1 GWh | 31.2 mi |
Locust Ridge | Mahanoy City, PA | 54.5 GWh | 31.8 mi |
Locust Ridge II LLC | Shenandoah, PA | 187.8 GWh | 31.1 mi |
Lycoming County | Montgomery, PA | 18.6 GWh | 14.2 mi |
Masser Farms Realty Solar | Sacramento, PA | 754.0 MWh | 29.9 mi |
Moxie Freedom Generation Plant | Salem Township, PA | 7.7 TWh | 26.7 mi |
St Nicholas Cogen Project | Shenandoah, PA | 607.1 GWh | 31 mi |
Sunbury Generation LP | Shamokin Dam, PA | 79.0 MWh | 18.2 mi |
Susquehanna University Solar | Selinsgrove, PA | 4.7 GWh | 22.1 mi |
TalenEnergy Susquehanna | Berwick, PA | 19.3 TWh | 27.2 mi |
Westwood Generation LLC | Tremont, PA | 156.3 GWh | 33.2 mi |