Rutgers Biomedical and Health Cogen
295 Norfolk Ave., Newark, NJ 7103Plant Summary Information
Rutgers Biomedical and Health Cogen is ranked #44 out of 378 power plants in New Jersey in terms of total annual net electricity generation.
Rutgers Biomedical and Health Cogen is comprised of 3 generators and generated 8.3 GWh during the 3-month period between May 2024 to August 2024.
Plant Name | Rutgers Biomedical and Health Cogen |
---|---|
Utility Name | Rutgers, The State University of NJ |
Location | Essex County, NJ |
Initial Operation Date | July 1989 |
Last Update | Aug 2024 |
Annual Generation | 30.0 GWh |
Annual Consumption | 330.0 k MMBtu |
Ranked #4,543 out of 11,835 Power Plants Nationwide | |
Ranked #1,281 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #44 out of 378 New Jersey Power Plants | |
Ranked #32 out of 55 New Jersey Natural Gas Power Plants | |
Fuel Types | Natural Gas |
Previous Operator |
University of M&D-New Jersey (2013 to 2015) Rutgers, The State University of NJ (2016 to 2023) |
Map of Rutgers Biomedical and Health Cogen
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Rutgers Biomedical and Health Cogen.
Monthly Net Generation for Rutgers Biomedical and Health Cogen
Rutgers Biomedical and Health Cogen Details
Summary Information | |
---|---|
Plant Name | Rutgers Biomedical and Health Cogen (50411) |
Plant Address | 295 Norfolk Ave., Newark, NJ 7103 |
Utility | Rutgers, The State University of NJ (58485) |
Latitude, Longitude | 40.73928, -74.18763 |
Generation Dates on File | Jan 2001 to Aug 2024 |
Initial Operation Date | July 1989 |
Annual Generation | 30.0 GWh |
Fuel Types | Natural Gas |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | RFC |
Balancing Authority | PJM Interconnection, LLC (PJM) |
NAICS Code | Hospitals (622) |
Sector | Commercial CHP (5) |
Water Source | Newark Water Company |
Ash Impoundment | No |
Transmission / Distribution Owner | Public Service Elec & Gas Co (15477) NJ |
Grid Voltage | 26.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | PUBLIC SERVICE ELECTRIC GAS CO |
Pipeline Name | PUBLIC SERVICE ELECTRIC & GAS CO |
Natural Gas Storage | No |
Generator GEN1 Details Operating July 1989
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3.5 MW |
Nameplate Power Factor | 0.96 |
Summer Capacity | 3.4 MW |
Winter Capacity | 3.7 MW |
Minimum Load | 2.3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 1989 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN2 Details Operating July 1989
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3.5 MW |
Nameplate Power Factor | 0.96 |
Summer Capacity | 3.4 MW |
Winter Capacity | 3.7 MW |
Minimum Load | 2.3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 1989 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN3 Details Operating July 1989
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 3.5 MW |
Nameplate Power Factor | 0.96 |
Summer Capacity | 3.4 MW |
Winter Capacity | 3.7 MW |
Minimum Load | 2.3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 1989 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | T |
Energy Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Rutgers Biomedical and Health Cogen Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1271 | Sherman Avenue | Vineland, NJ | 32.9 GWh |
#1272 | Darlington County | Hartsville, SC | 37.2 GWh |
#1273 | Ponca City | Ponca City, OK | 31.0 GWh |
#1274 | Indeck Yerkes Energy Center | Tonawanda, NY | 30.8 GWh |
#1275 | Hutchinson Plant #1 | Hutchinson, MN | 30.7 GWh |
#1276 | Jax LNG | Jacksonville, FL | 30.5 GWh |
#1277 | Summit Street Power Plant | Kent, OH | 30.5 GWh |
#1278 | P Plant | San Diego, CA | 30.5 GWh |
#1279 | Narrows Gas Turbines Generating | Brooklyn, NY | 31.4 GWh |
#1280 | Somerset Plant | Skowhegan, ME | 485.5 GWh |
#1282 | New Mexico State University | Las Cruces, NM | 30.0 GWh |
#1283 | CoreSite - Somerville | Somerville, MA | 29.8 GWh |
#1284 | McPherson 2 | McPherson, KS | 37.8 GWh |
#1285 | POET Biorefining - Marion, LLC | Marion, OH | 29.7 GWh |
#1286 | EQX015 Great Oaks Fuel Cell | San Jose, CA | 29.2 GWh |
#1287 | Astoria Gas Turbines | Astoria, NY | 33.5 GWh |
#1288 | Norton Powerhouse 2 | Worcester, MA | 28.9 GWh |
#1289 | Potter Station 2 | Braintree, MA | 32.3 GWh |
#1290 | Fuel Cell 18B Sneden Avenue | Staten Island, NY | 28.3 GWh |
#1291 | Mill Creek (KY) | Louisville, KY | 7.3 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Rutgers Biomedical and Health Cogen.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
435A Bergen Avenue | Kearney, NJ | 2.1 GWh | 3.1 mi |
601 Doremus CDG | Newark, NJ | 2.3 GWh | 3.6 mi |
Allied Beverages Elizabeth | Elizabeth, NJ | 5.4 GWh | 5.1 mi |
Bay Avenue CDG | Elizabeth, NJ | 56.0 MWh | 4.3 mi |
Community Foodbank of NJ | Hillside, NJ | 950.0 MWh | 3.2 mi |
Covanta Essex Company | Newark, NJ | 469.6 GWh | 3.3 mi |
Elizabeth Seaport Bldg A Solar | Elizabeth, NJ | 2.0 GWh | 5.4 mi |
Essex County Correctional Facility Cogen | Newark, NJ | 22.5 GWh | 3.5 mi |
Goya Foods, Inc- Secaucus Solar | Secaucus, NJ | 2.4 GWh | 6.2 mi |
Hudson County Solar | Kearny, NJ | 2.0 GWh | 4.2 mi |
Jersey Gardens Phase 1 | Elizabeth, NJ | 1.9 GWh | 5.5 mi |
Jersey Gardens Phase 2 | Elizabeth, NJ | 2.3 GWh | 5.5 mi |
Kenilworth Energy Facility | Kenilworth, NJ | 152.8 GWh | 6.2 mi |
Lister Avenue Solar | Newark, NJ | 1.2 GWh | 2.6 mi |
Newark Energy Center | Newark, NJ | 3.5 TWh | 3.9 mi |
NJMC Landfill | Kearny, NJ | 3.8 GWh | 4.1 mi |
Ports Jersey City Solar | Jersey City, NJ | 4.7 GWh | 5.3 mi |
Ports Newark 8201 Solar | Newark, NJ | 14.0 MWh | 3.3 mi |
PSEG Kearny Generating Station | Kearny, NJ | 132.3 GWh | 4.8 mi |
River Terminal Development Solar | Kearny, NJ | 3.4 GWh | 3.9 mi |