Rokeby
8000 SW 12 Street, Lincoln, NE 68523Plant Summary Information
Rokeby is ranked #40 out of 112 power plants in Nebraska in terms of total annual net electricity generation.
Rokeby is comprised of 4 generators and generated 15.1 GWh during the 3-month period between September 2022 to December 2022.
Plant Name | Rokeby |
---|---|
Utility Name | Lincoln Electric System |
Location | Lancaster County, NE |
Initial Operation Date | July 1975 |
Last Update | Dec 2022 |
Annual Generation | 72.5 GWh |
Annual Consumption | 1.0 M MMBtu |
Ranked #3,430 out of 11,249 Power Plants Nationwide | |
Ranked #1,004 out of 2,188 Natural Gas Power Plants Nationwide | |
Ranked #40 out of 112 Nebraska Power Plants | |
Ranked #5 out of 33 Nebraska Natural Gas Power Plants | |
Fuel Types | Natural Gas : 96.7% Distillate Fuel Oil : 3.3% |
Map of Rokeby
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Rokeby.
Monthly Net Generation for Rokeby
Rokeby Details
Summary Information | |
---|---|
Plant Name | Rokeby (6373) |
Plant Address | 8000 SW 12 Street Lincoln, NE 68523 |
Utility | Lincoln Electric System (11018) |
Latitude, Longitude | 40.7316, -96.7364 |
Generation Dates on File | Feb 2001 to Dec 2022 |
Initial Operation Date | July 1975 |
Annual Generation | 72.5 GWh |
Fuel Types | Natural Gas : 96.7% Distillate Fuel Oil : 3.3% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | MRO |
Balancing Authority | Southwest Power Pool (SWPP) |
NAICS Code | Utilities (22) |
Sector | Electric Utility (1) |
Water Source | Well |
Ash Impoundment | No |
Transmission / Distribution Owner | Lincoln Electric System (11018) NE |
Grid Voltage | 115.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | BLACK HILLS ENERGY |
Natural Gas Storage | No |
Generator 1 Details Operating July 1975
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LESROKEBYUN1_RA |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_ROKEBY_1 |
Nameplate Capacity | 72.4 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 70.5 MW |
Winter Capacity | 72 MW |
Minimum Load | 10 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | July 1975 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 72 MW |
Net Winter Capacity With Natural Gas | 72 MW |
Net Summer Capacity With Oil | 72 MW |
Net Winter Capacity With Oil | 72 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | No |
Generator BSU Details Operating April 1997
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 2.9 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 3.2 MW |
Winter Capacity | 3.2 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | April 1997 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Cofire Fuels | No |
Generator 2 Details Operating May 1997
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LESROKEBYUN2_RA |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_ROKEBY_2 |
Nameplate Capacity | 95.4 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 90.4 MW |
Winter Capacity | 91 MW |
Minimum Load | 20 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 1997 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 89 MW |
Net Winter Capacity With Natural Gas | 91 MW |
Net Summer Capacity With Oil | 84 MW |
Net Winter Capacity With Oil | 91 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Other Limits | Yes |
Generator 3 Details Operating May 2001
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | LESROKEBYUN3_RA |
RTO ISO Location Designation For Reporting Wholesale Sales Data | LES_ROKEBY_3 |
Nameplate Capacity | 95.4 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 94.2 MW |
Winter Capacity | 96 MW |
Minimum Load | 50 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2001 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 94 MW |
Net Winter Capacity With Natural Gas | 96 MW |
Net Summer Capacity With Oil | 96 MW |
Net Winter Capacity With Oil | 96 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 6H |
Factors That Limit Switching | Yes |
Other Limits | Yes |
Rokeby Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#994 | Essex | Essex, MO | 72.4 GWh |
#995 | Feather River Energy Center | Yuba City, CA | 72.2 GWh |
#996 | General Chemical | Green River, WY | 245.0 GWh |
#997 | International Paper Franklin Mill | Franklin, VA | 254.8 GWh |
#998 | Equus Freeport Power | Village of Freeport, NY | 72.5 GWh |
#999 | Fulton (AR) | Fulton, AR | 71.7 GWh |
#1000 | Brentwood | Long Island, NY | 70.9 GWh |
#1001 | Hopewell Mill | Hopewell, VA | 318.6 GWh |
#1002 | Pyramid | Lordsburg, NM | 74.3 GWh |
#1003 | Elk River | Elk River, MN | 70.2 GWh |
#1005 | Terry Bundy Generating Station | Lincoln, NE | 95.8 GWh |
#1006 | International Paper Red River Mill | Campti, LA | 385.3 GWh |
#1007 | CityCenter Central Plant Cogen Units | Las Vegas, NV | 69.8 GWh |
#1008 | Sylvamo Corporation Eastover Facility | Eastover, SC | 573.4 GWh |
#1009 | Univ of Massachusetts Medical Center | Worcester, MA | 71.2 GWh |
#1010 | Packaging Corp of America | Counce, TN | 434.7 GWh |
#1011 | Jamaica Bay Peaking | Far Rockaway, NY | 70.5 GWh |
#1012 | Nippon Dynawave Packaging Longview WA | Longview, WA | 310.7 GWh |
#1013 | Taft 26C Cogen | Taft, CA | 68.3 GWh |
#1014 | International Paper - Orange | Orange, TX | 298.1 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Rokeby.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Archer Daniels Midland Lincoln | Lincoln, NE | 32.9 GWh | 11.3 mi |
Beatrice | Beatrice, NE | 427.6 GWh | 28 mi |
Cass County | Plattsmouth, NE | 215.0 GWh | 43.1 mi |
Crete | Crete, NE | 99.2 MWh | 13.8 mi |
David City | David City, NE | 64.6 MWh | 41.3 mi |
Hallam | Hallam, NE | 1.9 GWh | 12.2 mi |
Holdrege Solar Center | Lincoln, NE | 7.1 GWh | 7.8 mi |
Lon Wright | Fremont, NE | 491.8 GWh | 50.2 mi |
Milligan 1 Wind Farm | Western, NE | 1.1 TWh | 30.8 mi |
Mobile | York, NE | 57.5 MWh | 46.4 mi |
Nebraska City | Nebraska City, NE | 6.3 TWh | 50.9 mi |
Perennial Windfarm | Fairmont, NE | 39.8 GWh | 48 mi |
Salt Valley Wind Plant | Lincoln, NE | 3.0 GWh | 13.3 mi |
Sarpy County | Bellevue, NE | 160.6 GWh | 50.2 mi |
Seward Wind Farm | Seward, NE | 8.8 GWh | 26.5 mi |
Sheldon | Hallam, NE | 723.6 GWh | 12.2 mi |
Steele Flats Wind Project LLC | Diller, NE | 292.2 GWh | 48.5 mi |
Terry Bundy Generating Station | Lincoln, NE | 95.8 GWh | 13.9 mi |
Wahoo | Wahoo, NE | 52.3 MWh | 33.8 mi |
Wilber | Wilber, NE | 11.5 MWh | 21 mi |