Milan
Milan Rd and Sunnyside Rd, Milan, PA 18831Plant Summary Information
Milan is ranked #49 out of 78 natural gas power plants in Pennsylvania in terms of total annual net electricity generation.
Milan is comprised of 3 generators and generated 10.8 GWh during the 3-month period between September 2023 to December 2023.
Plant Name | Milan |
---|---|
Utility Name | Milan Energy LLC |
Location | Bradford County, PA |
Initial Operation Date | March 2017 |
Last Update | Dec 2023 |
Annual Generation | 49.7 GWh |
Annual Consumption | 486.2 k MMBtu |
Ranked #3,851 out of 11,835 Power Plants Nationwide | |
Ranked #1,079 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #107 out of 231 Pennsylvania Power Plants | |
Ranked #49 out of 78 Pennsylvania Natural Gas Power Plants | |
Fuel Types | Natural Gas |
Map of Milan
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Milan.
Monthly Net Generation for Milan
Milan Details
Summary Information | |
---|---|
Plant Name | Milan (58818) |
Plant Address | Milan Rd and Sunnyside Rd, Milan, PA 18831 |
Utility | Milan Energy LLC (58689) |
Latitude, Longitude | 41.89444, -76.58278 |
Generation Dates on File | Mar 2017 to Dec 2023 |
Initial Operation Date | March 2017 |
Annual Generation | 49.7 GWh |
Fuel Types | Natural Gas |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | Yes |
FERC Exempt Wholesale Generator Docket Number | EG15-87 |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | RFC |
Balancing Authority | PJM Interconnection, LLC (PJM) |
NAICS Code | Utilities (22) |
Sector | IPP Non-CHP (2) |
Water Source | |
Ash Impoundment | No |
Transmission / Distribution Owner | Pennsylvania Electric Co (14711) PA |
Grid Voltage | 34.50 kV |
Energy Storage | No |
Natural Gas Information | |
Pipeline Name | None |
Natural Gas Storage | No |
Liquefied Natural Gas Storage | No |
Generator 1 Details Operating March 2017
Technology | Natural Gas Internal Combustion Engine |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | 1318143941 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | 1318143941 |
Nameplate Capacity | 7 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 6.8 MW |
Winter Capacity | 6.8 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
---|---|
Status | Operating |
First Operation Date | March 2017 |
Combined Heat & Power | No |
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator 2 Details Operating March 2017
Technology | Natural Gas Internal Combustion Engine |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | 1318143941 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | 1318143941 |
Nameplate Capacity | 7 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 6.8 MW |
Winter Capacity | 6.8 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
---|---|
Status | Operating |
First Operation Date | March 2017 |
Combined Heat & Power | No |
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator 3 Details Operating March 2017
Technology | Natural Gas Internal Combustion Engine |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
RTO ISO LMP Node Designation | 1318143941 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | 1318143941 |
Nameplate Capacity | 7 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 6.8 MW |
Winter Capacity | 6.8 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
---|---|
Status | Operating |
First Operation Date | March 2017 |
Combined Heat & Power | No |
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas |
Time From Cold Shutdown To Full Load | 10M |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Milan Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1069 | Warren F Sam Beasley Generation Station | Smyrna, DE | 52.9 GWh |
#1070 | Saint Marys Hospital Power Plant | Rochester, MN | 52.2 GWh |
#1071 | Kaukauna Paper Mill | Kaukauna, WI | 122.8 GWh |
#1072 | Inver Hills | Inver Grove Heights, MN | 78.2 GWh |
#1073 | Tesoro Kenai Cogeneration Plant | Kenai, AK | 50.9 GWh |
#1074 | A B Brown | Mount Vernon, IN | 290.3 GWh |
#1075 | St Francisville Mill | St. Francisville, LA | 116.0 GWh |
#1076 | TNSG North Plant | Deadhorse, AK | 50.5 GWh |
#1077 | Hunlock Unit 4 | Hunlock Green, PA | 50.3 GWh |
#1078 | Hoffmann LaRoche | Nutley, NJ | 50.1 GWh |
#1080 | APG Combined Heat and Power Plant | Edgewood, MD | 49.7 GWh |
#1081 | Bridgeport Gas Processing Plant | Bridgeport, TX | 49.6 GWh |
#1082 | AOC, Capitol Power Plant | Washington, DC | 49.4 GWh |
#1083 | Amalgamated Sugar LLC Nampa | Nampa, ID | 49.3 GWh |
#1084 | Yuba City Energy Center | Yuba City, CA | 49.3 GWh |
#1085 | Fortistar North Tonawanda | North Tonawanda, NY | 49.3 GWh |
#1086 | Cambridge CT Hybrid | Cambridge, MN | 49.4 GWh |
#1087 | Genesis Alkali | Green River, WY | 264.4 GWh |
#1088 | Georgia-Pacific Cedar Springs | Cedar Springs, GA | 573.3 GWh |
#1089 | International Paper Red River Mill | Campti, LA | 370.6 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Milan.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Alpaca | Canton Township, PA | 53.7 GWh | 19.7 mi |
Armenia Mountain Wind Farm | Mainesburg, PA | 224.0 GWh | 16.8 mi |
Beaver Dam | Canton Township, PA | 68.1 GWh | 23.7 mi |
Breesport Road Community Solar Farm | Baldwin, NY | 3.1 GWh | 15 mi |
Chambers Road Solar | Big Flats, NY | 6.1 GWh | 25.8 mi |
Gaskill Rd Community Solar Farm CSG | Owego, NY | 6.4 GWh | 25.6 mi |
Halsey Valley | Barton, NY | 8.1 GWh | 16.9 mi |
Hamilton Liberty | Towanda, PA | 6.0 TWh | 13.2 mi |
Hickory Grove #1 | Horseheads, NY | 3.0 GWh | 24.3 mi |
Hickory Grove #2 | Horseheads, NY | 2.8 GWh | 24.2 mi |
Hunt Creek | Nichols, NY | 5.8 GWh | 17.4 mi |
Norther Tier Landfill | Burlington, PA | 8.8 GWh | 8.3 mi |
Pasto Solar | Spencer, NY | 22.5 GWh | 22 mi |
Smith Creek | Nichols, NY | 6.4 GWh | 17.4 mi |
Tioga Solar North(CSG) | Owego, NY | 6.7 GWh | 22.8 mi |
Tioga Solar South(CSG) | Owego, NY | 6.7 GWh | 22.8 mi |
Towanda Facility | Wyalusing, PA | 15.4 GWh | 16.2 mi |
Turner Rd Community Solar Project | Baldwin, NY | 2.7 GWh | 14.6 mi |
Vulcraft Solar | Chemung, NY | 1.9 GWh | 7.9 mi |
Wolf Run Energy | Wilmot Township, PA | 66.1 GWh | 24.4 mi |