Maalaea

1000 N Kihei Road, Kihei, HI 96753

Plant Summary Information

Maalaea is ranked #1 out of 1,262 distillate fuel oil power plants nationwide in terms of total annual net electricity generation.

Maalaea is comprised of 21 generators and generated 129.4 GWh during the 3-month period between May 2024 to August 2024.

Plant NameMaalaea
Utility NameMaui Electric Co Ltd
LocationMaui County, HI
Initial Operation DateDecember 1971
Last Update Aug 2024
Annual Generation 601.9 GWh
Annual Consumption 6.2 M MMBtu
Ranked #1,087 out of 11,835 Power Plants Nationwide
Ranked #1 out of 1,262 Distillate Fuel Oil Power Plants Nationwide
Ranked #4 out of 65 Hawaii Power Plants
Ranked #1 out of 17 Hawaii Distillate Fuel Oil Power Plants
Fuel Types Distillate Fuel Oil

Map of Maalaea

Full Screen Map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Maalaea.

Create Your Account Today

Monthly Net Generation for Maalaea

Maalaea Details

Summary Information
Plant NameMaalaea (6504)
Plant Address1000 N Kihei Road, Kihei, HI 96753
UtilityMaui Electric Co Ltd (11843)
Latitude, Longitude20.80117, -156.49298
Generation Dates on FileJan 2001 to Aug 2024
Initial Operation DateDecember 1971
Annual Generation 601.9 GWh
Fuel Types Distillate Fuel Oil
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusNo
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusRegulated
NERC Region
Balancing Authority ()
NAICS CodeUtilities (22)
Sector Electric Utility (1)
Water SourceNA
Ash Impoundment No
Transmission / Distribution OwnerMaui Electric Co Ltd (11843) HI
Grid Voltage 69.00 kV
Energy StorageNo

Generator 1 Details Operating December 1971

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2.6 MW
Nameplate Power Factor0.8
Summer Capacity2.5 MW
Winter Capacity2.5 MW
Minimum Load2.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1971
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 2 Details Operating July 1972

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2.6 MW
Nameplate Power Factor0.8
Summer Capacity2.5 MW
Winter Capacity2.5 MW
Minimum Load2.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1972
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 3 Details Operating September 1972

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2.6 MW
Nameplate Power Factor0.8
Summer Capacity2.5 MW
Winter Capacity2.5 MW
Minimum Load2.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1972
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 4 Details Operating November 1973

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity5.6 MW
Nameplate Power Factor0.8
Summer Capacity5.5 MW
Winter Capacity5.5 MW
Minimum Load3 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1973
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 5 Details Operating December 1973

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity5.6 MW
Nameplate Power Factor0.8
Summer Capacity5.5 MW
Winter Capacity5.5 MW
Minimum Load3 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1973
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 6 Details Operating March 1975

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity5.6 MW
Nameplate Power Factor0.8
Summer Capacity5.5 MW
Winter Capacity5.5 MW
Minimum Load3 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1975
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 7 Details Operating August 1975

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity5.6 MW
Nameplate Power Factor0.8
Summer Capacity5.5 MW
Winter Capacity5.5 MW
Minimum Load3 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateAugust 1975
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 8 Details Operating November 1977

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity5.6 MW
Nameplate Power Factor0.8
Summer Capacity5.5 MW
Winter Capacity5.5 MW
Minimum Load3 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1977
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 9 Details Operating July 1978

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity5.6 MW
Nameplate Power Factor0.8
Summer Capacity5.5 MW
Winter Capacity5.5 MW
Minimum Load3 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1978
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 10 Details Operating December 1979

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity12.5 MW
Nameplate Power Factor0.8
Summer Capacity12.3 MW
Winter Capacity12.3 MW
Minimum Load8 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1979
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 11 Details Operating July 1980

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity12.5 MW
Nameplate Power Factor0.8
Summer Capacity12.3 MW
Winter Capacity12.3 MW
Minimum Load8 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1980
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator X1 Details Operating March 1987

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2.6 MW
Nameplate Power Factor0.8
Summer Capacity2.5 MW
Winter Capacity2.5 MW
Minimum Load2.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1987
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator X2 Details Operating March 1987

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2.6 MW
Nameplate Power Factor0.8
Summer Capacity2.5 MW
Winter Capacity2.5 MW
Minimum Load2.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1987
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 12 Details Operating April 1988

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity12.5 MW
Nameplate Power Factor0.8
Summer Capacity12.3 MW
Winter Capacity12.3 MW
Minimum Load8 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1988
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 13 Details Operating May 1989

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity12.5 MW
Nameplate Power Factor0.8
Summer Capacity12.3 MW
Winter Capacity12.3 MW
Minimum Load8 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1989
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 14 Details Operating May 1992

TechnologyPetroleum Liquids
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeCC1
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorYes
Nameplate Capacity23.6 MW
Nameplate Power Factor0.9
Summer Capacity21.1 MW
Winter Capacity21.1 MW
Minimum Load8 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1992
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 15 Details Operating October 1993

TechnologyPetroleum Liquids
Prime MoverCombined Cycle Steam Part
Unit CodeCC1
OwnershipSingle Owner
Duct BurnersNo
Nameplate Capacity18 MW
Nameplate Power Factor0.9
Summer Capacity12 MW
Winter Capacity12 MW
Minimum Load4 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateOctober 1993
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 16 Details Operating May 1993

TechnologyPetroleum Liquids
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeCC1
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorYes
Nameplate Capacity23.6 MW
Nameplate Power Factor0.9
Summer Capacity21.1 MW
Winter Capacity21.1 MW
Minimum Load8 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1993
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 17 Details Operating December 1998

TechnologyPetroleum Liquids
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeCC2
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorYes
Nameplate Capacity25 MW
Nameplate Power Factor0.8
Summer Capacity17.6 MW
Winter Capacity17.6 MW
Minimum Load14 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1998
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 19 Details Operating September 2000

TechnologyPetroleum Liquids
Prime MoverCombined Cycle Combustion Turbine Part
Unit CodeCC2
OwnershipSingle Owner
Can Bypass Heat Recovery Steam GeneratorYes
Nameplate Capacity25 MW
Nameplate Power Factor0.8
Summer Capacity17.6 MW
Winter Capacity17.6 MW
Minimum Load14 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 2000
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator 18 Details Operating October 2006

TechnologyPetroleum Liquids
Prime MoverCombined Cycle Steam Part
Unit CodeCC2
OwnershipSingle Owner
Duct BurnersNo
Nameplate Capacity18 MW
Nameplate Power Factor0.8
Summer Capacity13.8 MW
Winter Capacity13.8 MW
Minimum Load8.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateOctober 2006
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Maalaea Plant Owners

Owner NameAddressGeneratorOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Distillate Fuel Oil.

RankPlant NamePlant LocationAnnual Generation
#2KeaholeKailua Kona, HI266.0 GWh
#3Campbell Industrial ParkKapolei, HI123.4 GWh
#4Herbert A WagnerBaltimore, MD150.2 GWh
#5North PoleNorth Pole, AK483.0 GWh
#6Port Allen (HI)Eleele, HI73.7 GWh
#7WaiauPearl City, HI1.1 TWh
#8Cumberland (TN)Cumberland City, TN9.6 TWh
#9Morgan CreekColorado City, TX73.6 GWh
#10PunaKeaau, HI51.1 GWh
#11John E AmosSt Albans, WV8.8 TWh
#12Kapaia Power StationLihue, HI177.5 GWh
#13BethelBethel, AK43.9 GWh
#14Dutch HarborDutch Harbor, AK41.9 GWh
#15Gavin Power, LLCCheshire, OH13.0 TWh
#16Walter Scott Jr Energy CenterCouncil Bluffs, IA5.5 TWh
#17CardinalBrillant, OH10.0 TWh
#18Lake HubbardSunnyvale, TX899.7 GWh
#19LadysmithWoodford, VA660.1 GWh
#20Miki BasinLanai City, HI35.1 GWh
#21Monroe (MI)Monroe, MI13.0 TWh

Nearby Power Plants

Below are closest 20 power plants surrounding Maalaea.

Plant NamePlant LocationAnnual GenerationDistance
AES Maui Kuihelani Solar HybridWaikapu, HI16.1 GWh3 mi
AES Waikoloa Solar HybridWaikoloa Village, HI56.1 GWh78 mi
Auwahi Wind Energy HybridKula, HI83.6 GWh18.1 mi
Hamakua Energy PlantHonokaa, HI137.6 GWh82.2 mi
Hana SubstationHana, HI115.0 MWh32.2 mi
HNL Emergency Power FacilityHonolulu, HI2.5 GWh99.1 mi
Kaheawa Pastures Wind Farm HybridMaalaea, HI88.9 GWh3.9 mi
Kaheawa Wind Power II LLCWailuku, HI49.0 GWh2.8 mi
KahuluiKahului, HI140.0 GWh6.9 mi
KeaholeKailua Kona, HI266.0 GWh79.8 mi
Kihei Solar FarmKihei, HI1.3 GWh3.9 mi
Ku'ia SolarLahaina, HI5.0 GWh12.2 mi
Lanai Solar-Electric PlantLanai City, HI145.0 MWh27.9 mi
Miki BasinLanai City, HI35.1 GWh28.5 mi
Palaau Power HybridKaunakakai, HI31.1 GWh42.5 mi
Pearl City Peninsula Solar ParkHonolulu, HI1.3 GWh103 mi
WaiauPearl City, HI1.1 TWh103 mi
Waiawa Solar Power HybridWaipahu, HI57.0 GWh104.4 mi
WaimeaKamuela, HI1.7 GWh74.4 mi
Waipio PeninsulaWaipio, HI23.7 GWh103.8 mi