Hoffmann LaRoche
340 Kingsland Street, Nutley, NJ 7110Plant Summary Information
Hoffmann LaRoche is ranked #33 out of 378 power plants in New Jersey in terms of total annual net electricity generation.
Hoffmann LaRoche is comprised of 2 generators and generated 16.6 GWh during the 3-month period between May 2024 to August 2024.
Plant Name | Hoffmann LaRoche |
---|---|
Utility Name | PB Nutclif Master, LLC |
Location | Essex County, NJ |
Initial Operation Date | May 2004 |
Last Update | Aug 2024 |
Annual Generation | 50.1 GWh |
Annual Consumption | 729.8 k MMBtu |
Ranked #3,843 out of 11,835 Power Plants Nationwide | |
Ranked #1,078 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #33 out of 378 New Jersey Power Plants | |
Ranked #23 out of 55 New Jersey Natural Gas Power Plants | |
Fuel Types | Natural Gas |
Previous Operator |
Hoffman LaRoche Inc (2013 to 2015) PB Nutclif Master, LLC (2016 to 2023) |
Map of Hoffmann LaRoche
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Hoffmann LaRoche.
Monthly Net Generation for Hoffmann LaRoche
Hoffmann LaRoche Details
Summary Information | |
---|---|
Plant Name | Hoffmann LaRoche (10123) |
Plant Address | 340 Kingsland Street, Nutley, NJ 7110 |
Utility | PB Nutclif Master, LLC (60557) |
Latitude, Longitude | 40.8359, -74.155 |
Generation Dates on File | Jan 2001 to Aug 2024 |
Initial Operation Date | May 2004 |
Annual Generation | 50.1 GWh |
Fuel Types | Natural Gas |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | Yes |
FERC Cogeneration Docket Number | 85-91-000; '85-91-001 |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | RFC |
Balancing Authority | PJM Interconnection, LLC (PJM) |
NAICS Code | Chemical Manufacturing (325) |
Sector | Industrial CHP (7) |
Water Source | Passaic Valley Water Commissio |
Ash Impoundment | No |
Transmission / Distribution Owner | Public Service Elec & Gas Co (15477) NJ |
Grid Voltage | 26.40 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | PUBLIC SERVICE ELECTRIC GAS CO |
Natural Gas Storage | No |
Generator TG01 Details Operating May 2004
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 5.3 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 4.1 MW |
Winter Capacity | 5.3 MW |
Minimum Load | 2.8 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | May 2004 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Industrial CHP (7) |
Topping Or Bottoming | T |
Energy Source | Natural Gas / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 4.1 MW |
Net Winter Capacity With Natural Gas | 5.2 MW |
Net Summer Capacity With Oil | 4 MW |
Net Winter Capacity With Oil | 4.7 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator TG03 Details Operating May 2004
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 5.3 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 4.1 MW |
Winter Capacity | 5.3 MW |
Minimum Load | 2.8 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | May 2004 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Industrial CHP (7) |
Topping Or Bottoming | T |
Energy Source | Natural Gas / Distillate Fuel Oil |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 4.1 MW |
Net Winter Capacity With Natural Gas | 5.2 MW |
Net Summer Capacity With Oil | 4 MW |
Net Winter Capacity With Oil | 4.7 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Hoffmann LaRoche Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1068 | Loma Linda University Cogen | Loma Linda, CA | 52.3 GWh |
#1069 | Warren F Sam Beasley Generation Station | Smyrna, DE | 52.9 GWh |
#1070 | Saint Marys Hospital Power Plant | Rochester, MN | 52.2 GWh |
#1071 | Kaukauna Paper Mill | Kaukauna, WI | 122.8 GWh |
#1072 | Inver Hills | Inver Grove Heights, MN | 78.2 GWh |
#1073 | Tesoro Kenai Cogeneration Plant | Kenai, AK | 50.9 GWh |
#1074 | A B Brown | Mount Vernon, IN | 290.3 GWh |
#1075 | St Francisville Mill | St. Francisville, LA | 116.0 GWh |
#1076 | TNSG North Plant | Deadhorse, AK | 50.5 GWh |
#1077 | Hunlock Unit 4 | Hunlock Green, PA | 50.3 GWh |
#1079 | Milan | Milan, PA | 49.7 GWh |
#1080 | APG Combined Heat and Power Plant | Edgewood, MD | 49.7 GWh |
#1081 | Bridgeport Gas Processing Plant | Bridgeport, TX | 49.6 GWh |
#1082 | AOC, Capitol Power Plant | Washington, DC | 49.4 GWh |
#1083 | Amalgamated Sugar LLC Nampa | Nampa, ID | 49.3 GWh |
#1084 | Yuba City Energy Center | Yuba City, CA | 49.3 GWh |
#1085 | Fortistar North Tonawanda | North Tonawanda, NY | 49.3 GWh |
#1086 | Cambridge CT Hybrid | Cambridge, MN | 49.4 GWh |
#1087 | Genesis Alkali | Green River, WY | 264.4 GWh |
#1088 | Georgia-Pacific Cedar Springs | Cedar Springs, GA | 573.3 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Hoffmann LaRoche.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
435A Bergen Avenue | Kearney, NJ | 2.1 GWh | 5.9 mi |
46 Meadowlands Parkway | Secaucus, NJ | 2.5 GWh | 5.4 mi |
77 Metro Way | Secaucus, NJ | 1.5 GWh | 6.3 mi |
Bergen Generating Station | Ridgefield, NJ | 2.4 TWh | 6.8 mi |
Covanta Essex Company | Newark, NJ | 469.6 GWh | 7 mi |
EQX002 Secaucus Rd Fuel Cell | Secaucus, NJ | 10.4 GWh | 6.1 mi |
EQX003 Secaucus Rd Fuel Cell | Secaucus, NJ | 13.4 GWh | 5.9 mi |
EQX012 Harz Fuel Cell | Secaucus, NJ | 14.4 GWh | 5.8 mi |
Garfield Solar | Garfield Township, NJ | 5.9 GWh | 4 mi |
Goya Foods, Inc- Jersey City Solar | Jersey City, NJ | 3.5 GWh | 7 mi |
Goya Foods, Inc- Secaucus Solar | Secaucus, NJ | 2.4 GWh | 5.9 mi |
Great Falls Hydro Project | Paterson, NJ | 11.2 GWh | 5.7 mi |
Harmon DC Totowa NJ | Totowa, NJ | 1.8 GWh | 6.8 mi |
Hartz Way | Secaucus, NJ | 917.0 MWh | 5.7 mi |
Lister Avenue Solar | Newark, NJ | 1.2 GWh | 6.7 mi |
Mayhill Solar LLC Community Solar | Saddle Brook, NJ | 197.0 MWh | 5.6 mi |
Montclair State University Cogen | Little Falls, NJ | 47.0 GWh | 3 mi |
NJMC Landfill | Kearny, NJ | 3.8 GWh | 6.3 mi |
Rutgers Biomedical and Health Cogen | Newark, NJ | 30.0 GWh | 6.9 mi |
Wilzig Associates, LLC | East Rutherford, NJ | 1.4 GWh | 3.3 mi |