DSM Pharmaceuticals
5900 NW Martin Luther King Dr., Greenville, NC 27835Plant Summary Information
DSM Pharmaceuticals is ranked #47 out of 49 distillate fuel oil power plants in North Carolina in terms of total annual net electricity generation.
DSM Pharmaceuticals is comprised of 8 generators and generated 3.5 MWh during the 3-month period between September 2023 to December 2023.
Plant Name | DSM Pharmaceuticals |
---|---|
Utility Name | Patheon Manufacturing Service LLC |
Location | Pitt County, NC |
Initial Operation Date | August 1987 |
Last Update | Dec 2023 |
Annual Generation | 5.0 MWh |
Annual Consumption | 2.7 k MMBtu |
Ranked #11,804 out of 11,852 Power Plants Nationwide | |
Ranked #1,186 out of 1,262 Distillate Fuel Oil Power Plants Nationwide | |
Ranked #860 out of 863 North Carolina Power Plants | |
Ranked #47 out of 49 North Carolina Distillate Fuel Oil Power Plants | |
Fuel Types | Distillate Fuel Oil : 90.0% Natural Gas : 10.0% |
Previous Operator |
DSM Pharmaceuticals Inc (2013 to 2014) Patheon Manufacturing Service LLC (2015 to 2023) |
Map of DSM Pharmaceuticals
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for DSM Pharmaceuticals.
Monthly Net Generation for DSM Pharmaceuticals
DSM Pharmaceuticals Details
Summary Information | |
---|---|
Plant Name | DSM Pharmaceuticals (54887) |
Plant Address | 5900 NW Martin Luther King Dr., Greenville, NC 27835 |
Utility | Patheon Manufacturing Service LLC (59895) |
Latitude, Longitude | 35.66596, -77.35744 |
Generation Dates on File | Jan 2001 to Dec 2023 |
Initial Operation Date | August 1987 |
Annual Generation | 5.0 MWh |
Fuel Types | Distillate Fuel Oil : 90.0% Natural Gas : 10.0% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | Yes |
FERC Cogeneration Docket Number | 93-32-000 |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | SERC |
Balancing Authority | Duke Energy Progress East (CPLE) |
NAICS Code | Chemical Manufacturing (325) |
Sector | Industrial CHP (7) |
Water Source | |
Ash Impoundment | No |
Transmission / Distribution Owner | Greenville Utilities Comm (7639) NC |
Grid Voltage | 13.20 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | GREENVILLE UTILITIES COMMISSION |
Natural Gas Storage | No |
Generator GEN4 Details Standby August 1987
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 1.2 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.2 MW |
Winter Capacity | 1.2 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | Yes |
First Operation Date | August 1987 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN1 Details Standby August 1993
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 4 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 3.5 MW |
Winter Capacity | 4 MW |
Minimum Load | 0.5 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | Yes |
First Operation Date | August 1993 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Industrial CHP (7) |
Topping Or Bottoming | T |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 3.5 MW |
Net Winter Capacity With Natural Gas | 3.5 MW |
Net Summer Capacity With Oil | 3.5 MW |
Net Winter Capacity With Oil | 3.6 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator GEN2 Details Standby October 1994
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 0.3 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 0.3 MW |
Winter Capacity | 0.3 MW |
Minimum Load | 0.3 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | Yes |
First Operation Date | October 1994 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN3 Details Standby July 1994
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 1.1 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.1 MW |
Winter Capacity | 1.1 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | Yes |
First Operation Date | July 1994 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN5 Details Standby July 1999
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 1 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1 MW |
Winter Capacity | 1 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | Yes |
First Operation Date | July 1999 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN6 Details Standby November 2003
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 1.2 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 1.2 MW |
Winter Capacity | 1.2 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | Yes |
First Operation Date | November 2003 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN7 Details Standby August 2015
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 0.1 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 0.1 MW |
Winter Capacity | 0.1 MW |
Minimum Load | 0.1 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | No |
First Operation Date | August 2015 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
Generator GEN8 Details Standby August 2015
Technology | Petroleum Liquids |
---|---|
Prime Mover | Internal Combustion Engine |
Ownership | Single Owner |
Nameplate Capacity | 0.3 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 0.3 MW |
Winter Capacity | 0.3 MW |
Minimum Load | 0.3 MW |
Uprate/Derate Completed | No |
Status | Standby |
Synchronized To Transmission Grid | No |
First Operation Date | August 2015 |
---|---|
Combined Heat & Power | No |
Sector Name | Industrial CHP (7) |
Energy Source | Distillate Fuel Oil |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 10M |
Other Planned Modifications | No |
Multiple Fuels | No |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | No |
DSM Pharmaceuticals Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Distillate Fuel Oil.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1176 | Rio Grande Valley Sugar Growers | Santa Rosa, TX | 92.0 MWh |
#1177 | Drexel Operations Center | Drexel, NC | 5.0 MWh |
#1178 | Catawba River Pollution Control | Morganton, NC | 5.0 MWh |
#1179 | Osawatomie Power Plant North Sub | Osawatomie, KS | 5.0 MWh |
#1180 | Anderson | Anderson, IN | 47.6 GWh |
#1181 | Dodge Park Engine No 1 | Columbus, OH | 4.9 MWh |
#1182 | Anthony | Anthony, KS | 41.0 MWh |
#1183 | Univ Minnesota CHP Plant | Minneapolis, MN | 173.9 GWh |
#1184 | Osborne | Osborne, KS | 7.8 MWh |
#1185 | Richmond | Centerville, IN | 13.6 GWh |
#1187 | University of Rochester | Rochester, NY | 32.5 GWh |
#1188 | Island Street Peaking Plant | Kaukauna, WI | 8.0 GWh |
#1189 | Curtis | Curtis, NE | 17.0 MWh |
#1190 | Gowrie | Gowrie, IA | 4.0 MWh |
#1191 | McGregor | McGregor, IA | 4.0 MWh |
#1192 | Wellington 1 | Wellington, KS | 3.4 GWh |
#1193 | New Castle Plant | West Pittsburg, PA | 898.1 GWh |
#1194 | Colchester 16 | Colchester, VT | 4.0 MWh |
#1195 | Viola | Viola, WI | 4.0 MWh |
#1196 | Brooklyn City North Plant | Brooklyn, IA | 4.0 MWh |
Nearby Power Plants
Below are closest 20 power plants surrounding DSM Pharmaceuticals.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Augustus Farm, LLC | Farmville, NC | 9.6 GWh | 16.5 mi |
Beaker | Farmville, NC | 10.4 GWh | 14.9 mi |
Bethel Price Solar, LLC | Bethel, NC | 6.5 GWh | 9 mi |
Bethel Solar | Bethel, NC | 7.7 GWh | 9 mi |
Carolina Poultry Power Farmville | Farmville, NC | 4.0 GWh | 15.3 mi |
Chocowinity Solar LLC | Chocowinity, NC | 8.0 GWh | 18.3 mi |
Conetoe II Solar, LLC | Conetoe, NC | 145.7 GWh | 12.8 mi |
Conetoe Solar | Tarboro, NC | 8.7 GWh | 12.4 mi |
Everett PV1 | Parmele, NC | 19.3 GWh | 11.1 mi |
Flat Meeks PV 1 | Robersonville, NC | 9.0 GWh | 10.9 mi |
Flemming Solar Center LLC | Greenville, NC | 8.4 GWh | 1.5 mi |
Green Farm | Robersonville, NC | 9.3 GWh | 12.5 mi |
Littlefield Solar Center LLC | Ayden, NC | 8.9 GWh | 16.7 mi |
Meadows PV 1 | Williamston, NC | 18.2 GWh | 17.5 mi |
Meeks Solar, LLC | Robersonville, NC | 3.6 GWh | 11 mi |
Penny Hill Solar | Greenville, NC | 3.7 GWh | 10.8 mi |
Rams Horn Solar Center LLC | Greenville, NC | 7.3 GWh | 2.8 mi |
Tarboro Solar | Tarboro, NC | 8.7 GWh | 15.5 mi |
TWE Chocowinity Solar, LLC | Chocowinity, NC | 5.9 GWh | 18.1 mi |
Williamston West Farm, LLC | Williamston, NC | 4.3 GWh | 18.3 mi |