Dania Beach 7
4300 SW 42nd Avenue, Ft. Lauderdale, FL 33314Plant Summary Information
Dania Beach 7 is ranked #14 out of 279 power plants in Florida in terms of total annual net electricity generation.
Dania Beach 7 is comprised of 3 generators and generated 2.1 TWh during the 3-month period between June 2024 to September 2024.
Plant Name | Dania Beach 7 |
---|---|
Utility Name | Florida Power & Light Co |
Location | Broward County, FL |
Initial Operation Date | May 2022 |
Last Update | Sep 2024 |
Annual Generation | 6.6 TWh |
Annual Consumption | 46.9 M MMBtu |
Ranked #145 out of 11,852 Power Plants Nationwide | |
Ranked #59 out of 2,254 Natural Gas Power Plants Nationwide | |
Ranked #14 out of 279 Florida Power Plants | |
Ranked #13 out of 85 Florida Natural Gas Power Plants | |
Fuel Types | Natural Gas |
Map of Dania Beach 7
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Dania Beach 7.
Monthly Net Generation for Dania Beach 7
Dania Beach 7 Details
Summary Information | |
---|---|
Plant Name | Dania Beach 7 (65978) |
Plant Address | 4300 SW 42nd Avenue, Ft. Lauderdale, FL 33314 |
Utility | Florida Power & Light Co (6452) |
Latitude, Longitude | 26.0686, -80.1984 |
Generation Dates on File | May 2022 to Sep 2024 |
Initial Operation Date | May 2022 |
Annual Generation | 6.6 TWh |
Fuel Types | Natural Gas |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | SERC |
Balancing Authority | Florida Power & Light Company (FPL) |
NAICS Code | Utilities (22) |
Sector | Electric Utility (1) |
Water Source | Dania Cut Off Canel |
Ash Impoundment | |
Transmission / Distribution Owner | Florida Power & Light Co (6452) FL |
Grid Voltage | 230.00 kV |
Energy Storage | No |
Natural Gas Information | |
Pipeline Name | FLORIDA GAS TRANSMISSION COMPANY |
Natural Gas Storage | No |
Generator 7GT1 Details Operating May 2022
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | DBCC |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
Nameplate Capacity | 492.2 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 434.1 MW |
Winter Capacity | 432.2 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2022 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | No |
---|---|
Net Summer Capacity With Natural Gas | 434.1 MW |
Net Winter Capacity With Natural Gas | 432.2 MW |
Net Summer Capacity With Oil | 370.3 MW |
Net Winter Capacity With Oil | 413.2 MW |
Time To Switch From Gas To Oil | UNK |
Time To Switch From Oil To Gas | UNK |
Factors That Limit Switching | No |
Generator 7GT2 Details Operating May 2022
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | DBCC |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
Nameplate Capacity | 492.2 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 434.1 MW |
Winter Capacity | 432.2 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2022 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | No |
---|---|
Net Summer Capacity With Natural Gas | 434.1 MW |
Net Winter Capacity With Natural Gas | 432.2 MW |
Net Summer Capacity With Oil | 370.3 MW |
Net Winter Capacity With Oil | 413.2 MW |
Time To Switch From Gas To Oil | UNK |
Time To Switch From Oil To Gas | UNK |
Factors That Limit Switching | No |
Generator ST7 Details Operating May 2022
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Steam Part |
Unit Code | DBCC |
Ownership | Single Owner |
Duct Burners | No |
Nameplate Capacity | 463.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 377.8 MW |
Winter Capacity | 369.6 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | May 2022 |
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | No |
---|---|
Net Summer Capacity With Natural Gas | 377.8 MW |
Net Winter Capacity With Natural Gas | 369.6 MW |
Net Summer Capacity With Oil | 322.3 MW |
Net Winter Capacity With Oil | 353.4 MW |
Time To Switch From Gas To Oil | UNK |
Time To Switch From Oil To Gas | UNK |
Factors That Limit Switching | No |
Dania Beach 7 Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#49 | CPV Three Rivers Energy Center | Morris, IL | 6.8 TWh |
#50 | Jack County | Bridgeport, TX | 6.8 TWh |
#51 | CPV Fairview Energy Center | Johnstown, PA | 6.8 TWh |
#52 | Tenaska Westmoreland Generating Station | Smithton, PA | 6.7 TWh |
#53 | Chouteau | Pryor, OK | 6.7 TWh |
#54 | Victor J Daniel Jr | Escatawpa, MS | 8.2 TWh |
#55 | Chuck Lenzie Generating Station | Apex, NV | 6.6 TWh |
#56 | Waterford Power, LLC | Waterford, OH | 6.6 TWh |
#57 | Lee Combined Cycle Plant | Goldsboro, NC | 6.6 TWh |
#58 | Oregon Clean Energy Center | Oregon, OH | 6.6 TWh |
#60 | Marcus Hook Energy LP | Marcus Hook, PA | 6.6 TWh |
#61 | Magnolia Power Plant | Ashland, MS | 6.5 TWh |
#62 | Clean Energy Future-Lordstown, LLC | Lordstown, OH | 6.5 TWh |
#63 | Hamilton Patriot Generation Plant | Montgomery, PA | 6.4 TWh |
#64 | Cape Canaveral | Cocoa, FL | 6.3 TWh |
#65 | Allen | Memphis, TN | 6.2 TWh |
#66 | P L Bartow | St. Petersburg, FL | 6.2 TWh |
#67 | Bethlehem Power Plant | Bethlehem, PA | 6.1 TWh |
#68 | Montgomery County | Willis, TX | 6.1 TWh |
#69 | Belews Creek | Belews Creek, NC | 8.9 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Dania Beach 7.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
CSL Gas Recovery | Pompano Beach, FL | 40.0 GWh | 15.3 mi |
Everglades Solar Energy Center | Homestead, FL | 141.7 GWh | 42.6 mi |
FIU Solar | Miami, FL | 1.5 GWh | 23.2 mi |
Hibiscus Solar Energy Center | Westlake, FL | 145.9 GWh | 48.2 mi |
IKEA Miami 327 | Miami, FL | 1.4 GWh | 22.3 mi |
Lauderdale | Ft. Lauderdale, FL | 262.3 GWh | 0 mi |
Miami Dade County Resource Recovery Fac | Miami, FL | 233.7 GWh | 18.9 mi |
Miami Dade Solar Energy Center | Miami, FL | 129.7 GWh | 34.7 mi |
Okeelanta Cogeneration | South Bay, FL | 40.5 GWh | 48.9 mi |
Palm Beach Renewable Energy Facility 1 | West Palm Beach, FL | 319.5 GWh | 48.7 mi |
Palm Beach Renewable Energy Facility 2 | West Palm Beach, FL | 530.6 GWh | 48.8 mi |
Pembroke Lakes Mall | Pembroke Pines, FL | 596.0 MWh | 7.7 mi |
Port Everglades | Ft. Lauderdale, FL | 5.2 TWh | 4.7 mi |
Riviera | Riviera Beach, FL | 7.6 TWh | 49 mi |
Sabal Palm Solar Center | Loxahatchee, FL | 153.1 GWh | 50.3 mi |
South District Wastewater Treatment Plt | Miami, FL | 22.6 GWh | 36.9 mi |
Tom G Smith | Lake Worth, FL | 444.0 MWh | 38.5 mi |
Turkey Point | Homestead, FL | 21.4 TWh | 44.5 mi |
West County Energy Center | Loxahatchee, FL | 21.0 TWh | 44.9 mi |
Wheelabrator South Broward | Ft. Lauderdale, FL | 414.3 GWh | 0 mi |