Covanta Niagara I, LLC
100 Energy Blvd & 56th St, Niagara Falls, NY 14304Plant Summary Information
Covanta Niagara I, LLC is ranked #32 out of 59 non-biogenic municipal solid waste power plants nationwide in terms of total annual net electricity generation.
Covanta Niagara I, LLC is comprised of 2 generators and generated 41.3 GWh during the 3-month period between June 2024 to September 2024.
Plant Name | Covanta Niagara I, LLC |
---|---|
Utility Name | Covanta Energy of Niagara LP |
Location | Niagara County, NY |
Initial Operation Date | August 1980 |
Last Update | Sep 2024 |
Annual Generation | 183.6 GWh |
Annual Consumption | 8.2 M MMBtu |
Ranked #2,420 out of 11,852 Power Plants Nationwide | |
Ranked #32 out of 59 NON-Biogenic Municipal Solid Waste Power Plants Nationwide | |
Ranked #59 out of 832 New York Power Plants | |
Ranked #5 out of 10 New York NON-Biogenic Municipal Solid Waste Power Plants | |
Fuel Types | Non-biogenic Municipal Solid Waste : 51.0% Biogenic Municipal Solid Waste : 41.7% Natural Gas : 7.2% |
Map of Covanta Niagara I, LLC
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Covanta Niagara I, LLC.
Monthly Net Generation for Covanta Niagara I, LLC
Covanta Niagara I, LLC Details
Summary Information | |
---|---|
Plant Name | Covanta Niagara I, LLC (50472) |
Plant Address | 100 Energy Blvd & 56th St, Niagara Falls, NY 14304 |
Utility | Covanta Energy of Niagara LP (470) |
Latitude, Longitude | 43.0839, -79.0056 |
Generation Dates on File | Jan 2001 to Sep 2024 |
Initial Operation Date | August 1980 |
Annual Generation | 183.6 GWh |
Fuel Types | Non-biogenic Municipal Solid Waste : 51.0% Biogenic Municipal Solid Waste : 41.7% Natural Gas : 7.2% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | Yes |
FERC Cogeneration Docket Number | 82-83-003, 82-83-002 |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | NPCC |
Balancing Authority | New York Independent System Operator (NYIS) |
NAICS Code | Solid Waste Combustors and Incinerators (562213) |
Sector | Commercial CHP (5) |
Water Source | Niagara River & Municipality |
Ash Impoundment | No |
Transmission / Distribution Owner | Niagara Mohawk Power Corp. (13573) NY |
Grid Voltage | 115.00 kV |
Energy Storage | No |
Natural Gas Information | |
Pipeline Name | NATIONAL FUEL GAS SUPPLY CORPORATION |
Natural Gas Storage | No |
Generator GEN1 Details Operating August 1980
Technology | Municipal Solid Waste |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 25 MW |
Nameplate Power Factor | 0.8 |
Summer Capacity | 18 MW |
Winter Capacity | 18 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 1980 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | B |
Energy Source | Municipal Solid Waste / Natural Gas |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | NG / MSW / WDS / OTH |
---|
Generator GEN2 Details Operating August 1980
Technology | Municipal Solid Waste |
---|---|
Prime Mover | Steam Turbine |
Ownership | Single Owner |
Nameplate Capacity | 25 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 18 MW |
Winter Capacity | 18 MW |
Minimum Load | 3 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | August 1980 |
Combined Heat & Power | Yes |
---|---|
Sector Name | Commercial CHP (5) |
Topping Or Bottoming | B |
Energy Source | Municipal Solid Waste / Natural Gas |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | NG / MSW / WDS / OTH |
---|
Covanta Niagara I, LLC Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Non-biogenic Municipal Solid Waste.
Nearby Power Plants
Below are closest 20 power plants surrounding Covanta Niagara I, LLC.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
AES Tonawanda Solar LLC | Tonawanda, NY | 2.9 GWh | 8 mi |
Amherst Community Solar | Amherst, NY | 6.0 GWh | 13.3 mi |
Bizer Creek | Getzville, NY | 1.7 GWh | 12.2 mi |
Buffalo NY GigaFactory | Buffalo, NY | 2.6 GWh | 17.6 mi |
Corning Riverview (CSG) | Tonawanda, NY | 7.5 GWh | 7.4 mi |
Fortistar North Tonawanda | North Tonawanda, NY | 49.3 GWh | 8 mi |
Hydraulic Race | Lockport, NY | 8.1 GWh | 16.9 mi |
Indeck Yerkes Energy Center | Tonawanda, NY | 30.8 GWh | 9.2 mi |
Lockport Energy Associates LP | Lockport, NY | 96.0 GWh | 14.2 mi |
LR Wheatfield Solar 1 | Wheatfield, NY | 8.3 GWh | 5.3 mi |
Millersport GM 1 | Amherst, NY | 6.4 GWh | 12.6 mi |
Model City Energy Facility | Youngstown, NY | 28.6 GWh | 8.7 mi |
Modern Innovative Energy LLC | Youngstown, NY | 33.7 GWh | 8.7 mi |
Moore Road Community Solar | Ransomville, NY | 5.6 GWh | 10.3 mi |
Niagara Depot Solar | Niagara Falls, NY | 2.4 GWh | 2.4 mi |
Pendleton Solar 1 | Lockport, NY | 7.1 GWh | 12.7 mi |
Ransomville Solar 1, LLC | Ransomville, NY | 6.1 GWh | 8.5 mi |
Robert Moses Niagara | Lewiston, NY | 15.8 TWh | 4.4 mi |
Steel Winds Wind Farm | Lackawanna, NY | 59.5 GWh | 19.7 mi |
Williams Rd | Ransomville, NY | 5.9 GWh | 8.9 mi |