Coit GT
300 Heyward Street, Columbia, SC 29201Plant Summary Information
Coit GT is ranked #23 out of 25 natural gas power plants in South Carolina in terms of total annual net electricity generation.
Coit GT is comprised of 2 generators and generated 91.1 MWh during the 3-month period between September 2023 to December 2023.
Plant Name | Coit GT |
---|---|
Utility Name | Dominion Energy South Carolina, Inc |
Location | Richland County, SC |
Initial Operation Date | May 1964 |
Last Update | Dec 2023 |
Annual Generation | 400.0 MWh |
Annual Consumption | 17.4 k MMBtu |
Ranked #11,092 out of 11,835 Power Plants Nationwide | |
Ranked #2,005 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #180 out of 190 South Carolina Power Plants | |
Ranked #23 out of 25 South Carolina Natural Gas Power Plants | |
Fuel Types | Natural Gas : 88.0% Distillate Fuel Oil : 12.0% |
Previous Operator |
South Carolina Electric&Gas Company (2013 to 2017) Dominion Energy South Carolina, Inc (2018 to 2023) |
Map of Coit GT
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Coit GT.
Monthly Net Generation for Coit GT
Coit GT Details
Summary Information | |
---|---|
Plant Name | Coit GT (3281) |
Plant Address | 300 Heyward Street, Columbia, SC 29201 |
Utility | Dominion Energy South Carolina, Inc (17539) |
Latitude, Longitude | 33.98025, -81.04067 |
Generation Dates on File | Jan 2001 to Dec 2023 |
Initial Operation Date | May 1964 |
Annual Generation | 400.0 MWh |
Fuel Types | Natural Gas : 88.0% Distillate Fuel Oil : 12.0% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | SERC |
Balancing Authority | Dominion Energy South Carolina (SCEG) |
NAICS Code | Utilities (22) |
Sector | Electric Utility (1) |
Water Source | |
Ash Impoundment | No |
Transmission / Distribution Owner | Dominion Energy South Carolina, Inc (17539) SC |
Grid Voltage | 33.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | Other - See pipeline notes. |
Pipeline Notes | Coit LDC is Dominion Energy South Carolina. |
Generator 2 Details Operating May 1969
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 19.6 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 12 MW |
Winter Capacity | 18 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | May 1969 |
Planned Retirement | December 2025 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 12 MW |
Net Winter Capacity With Natural Gas | 18 MW |
Net Summer Capacity With Oil | 12 MW |
Net Winter Capacity With Oil | 18 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Generator 1 Details Operating July 1969
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 19.6 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 14 MW |
Winter Capacity | 18 MW |
Minimum Load | 1 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | July 1969 |
Planned Retirement | December 2025 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 14 MW |
Net Winter Capacity With Natural Gas | 18 MW |
Net Summer Capacity With Oil | 14 MW |
Net Winter Capacity With Oil | 18 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Air Permit Limits | Yes |
Coit GT Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#1995 | Praxair | Clute, TX | 364.0 MWh |
#1996 | WAL536 | Abilene, TX | 362.0 MWh |
#1997 | WAL3390 | The Woodlands, TX | 361.0 MWh |
#1998 | Barber Creek | Gillette, WY | 359.0 MWh |
#1999 | WAL266 | Grapevine, TX | 358.0 MWh |
#2000 | WAL284 | Mansfield, TX | 356.0 MWh |
#2001 | City of Hayward WWTP | Hayward, CA | 10.3 GWh |
#2002 | WAL5316 | Saginaw, TX | 354.0 MWh |
#2003 | WAL4509 | Tarrant, TX | 353.0 MWh |
#2004 | WAL896 | Grand Prairie, TX | 352.0 MWh |
#2006 | HEB00109 | Katy, TX | 346.0 MWh |
#2007 | HEB00099 | Houston, TX | 345.0 MWh |
#2008 | Alamosa | Alamosa, CO | 7.8 GWh |
#2009 | Centech Gas Generator | Shrewsbury, MA | 340.0 MWh |
#2010 | Waterloo | Waterloo, IL | 462.0 MWh |
#2011 | WAL940 | Westworth Village, TX | 338.0 MWh |
#2012 | WAL1103 | Houston, TX | 338.0 MWh |
#2013 | WAL5116 | Deer Park, TX | 338.0 MWh |
#2014 | HEB00028 | League City, TX | 338.0 MWh |
#2015 | WAL5480 | Round Rock, TX | 334.0 MWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Coit GT.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Allora Solar, LLC | Gilbert, SC | 165.3 GWh | 21.4 mi |
Champion Solar | Pelion, SC | 21.2 GWh | 18.1 mi |
Columbia Energy Center (SC) | Gaston, SC | 2.8 TWh | 7.8 mi |
Diamond Solar | Pelion, SC | 10.0 GWh | 18.9 mi |
Eastover Solar | Eastover, SC | 138.1 GWh | 23 mi |
Gaston II | Swansea, SC | 9.8 GWh | 14.5 mi |
Gaston Solar I - SC | Gaston, SC | 20.1 GWh | 14.8 mi |
Gunsight Solar, LLC | Swansea, SC | 173.6 GWh | 15.2 mi |
McMeekin | Columbia, SC | 882.6 GWh | 11.4 mi |
Midlands | St. Matthews, SC | 147.8 GWh | 23.6 mi |
Odyssey Solar | Pelion, SC | 17.5 GWh | 18.4 mi |
Otarre Solar Park | Cayce, SC | 2.8 GWh | 3.4 mi |
Parr GT | Jenkinsville, SC | 3.1 GWh | 25.7 mi |
Parr Hydro | Jenkinsville, SC | 46.9 GWh | 25.5 mi |
Richland County Landfill | Lugoff, SC | 12.1 GWh | 16.6 mi |
Saluda Lexington | Columbia, SC | 109.5 GWh | 11.3 mi |
St. Matthews Solar | Matthews, SC | 19.3 GWh | 26 mi |
Swamp Fox Solar | Pelion, SC | 22.9 GWh | 18 mi |
Sylvamo Corporation Eastover Facility | Eastover, SC | 558.8 GWh | 23.9 mi |
Wateree | Eastover, SC | 2.1 TWh | 26.2 mi |