Bridgeport Station
2 Atlantic Street, Bridgeport, CT 6604Plant Summary Information
Bridgeport Station is ranked #5 out of 156 power plants in Connecticut in terms of total annual net electricity generation.
Bridgeport Station is comprised of 2 generators and generated 1.0 TWh during the 3-month period between June 2024 to September 2024.
Plant Name | Bridgeport Station |
---|---|
Utility Name | Generation Bridge II Connecticut, LLC |
Location | Greater Bridgeport Planning Region, CT |
Initial Operation Date | August 1961 |
Last Update | Sep 2024 |
Annual Generation | 3.3 TWh |
Annual Consumption | 23.7 M MMBtu |
Ranked #354 out of 11,852 Power Plants Nationwide | |
Ranked #210 out of 2,254 Natural Gas Power Plants Nationwide | |
Ranked #5 out of 156 Connecticut Power Plants | |
Ranked #4 out of 55 Connecticut Natural Gas Power Plants | |
Fuel Types | Natural Gas |
Previous Operator |
PSEG Power Connecticut LLC (2013 to 2021) Generation Bridge II Connecticut, LLC (2022 to 2023) |
Map of Bridgeport Station
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Bridgeport Station.
Monthly Net Generation for Bridgeport Station
Bridgeport Station Details
Summary Information | |
---|---|
Plant Name | Bridgeport Station (568) |
Plant Address | 2 Atlantic Street, Bridgeport, CT 6604 |
Utility | Generation Bridge II Connecticut, LLC (65448) |
Latitude, Longitude | 41.1706, -73.1844 |
Generation Dates on File | Jan 2001 to Sep 2024 |
Initial Operation Date | August 1961 |
Annual Generation | 3.3 TWh |
Fuel Types | Natural Gas |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | Yes |
FERC Exempt Wholesale Generator Docket Number | 03-25-000 |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | NPCC |
Balancing Authority | ISO New England Inc. (ISNE) |
NAICS Code | Utilities (22) |
Sector | IPP Non-CHP (2) |
Water Source | Aquarion Water Co |
Ash Impoundment | No |
Transmission / Distribution Owner | United Illuminating Co (19497) CT |
Grid Voltage | 345.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | SOUTHERN CONNECTICUT GAS COMPANY |
Natural Gas Storage | No |
Generator 501 Details Operating June 2019
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Combustion Turbine Part |
Unit Code | CC1 |
Ownership | Single Owner |
Can Bypass Heat Recovery Steam Generator | No |
RTO ISO LMP Node Designation | UN.BPT 5CC25 bhr5 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | UN.BPT 5CC25 bhr5 |
Nameplate Capacity | 375.7 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 337 MW |
Winter Capacity | 359 MW |
Minimum Load | 155 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | June 2019 |
Combined Heat & Power | No |
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 337 MW |
Net Winter Capacity With Natural Gas | 359 MW |
Net Summer Capacity With Oil | 337 MW |
Net Winter Capacity With Oil | 345 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 502 Details Operating June 2019
Technology | Natural Gas Fired Combined Cycle |
---|---|
Prime Mover | Combined Cycle Steam Part |
Unit Code | CC1 |
Ownership | Single Owner |
Duct Burners | Yes |
RTO ISO LMP Node Designation | UN.BPT 5CC25 bhr5 |
RTO ISO Location Designation For Reporting Wholesale Sales Data | UN.BPT 5CC25 bhr5 |
Nameplate Capacity | 200.6 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 145.8 MW |
Winter Capacity | 149.6 MW |
Minimum Load | 82 MW |
Uprate/Derate Completed | No |
Status | Operating |
---|---|
First Operation Date | June 2019 |
Combined Heat & Power | No |
Sector Name | IPP Non-CHP (2) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Subcritical Technology | Yes |
Other Planned Modifications | No |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 145.8 MW |
Net Winter Capacity With Natural Gas | 149.6 MW |
Net Summer Capacity With Oil | 145 MW |
Net Winter Capacity With Oil | 145.8 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Bridgeport Station Plant Owners
Owner Name | Address | Generator | Ownership |
---|---|---|---|
Public Service Elec & Gas Co | P O Box 57080 Park Plaza, T9B, Newark, NJ 7102 | Generator 2 | 100.00% |
Public Service Elec & Gas Co | P O Box 57080 Park Plaza, T9B, Newark, NJ 7102 | Generator 3 | 100.00% |
Public Service Elec & Gas Co | P O Box 57080 Park Plaza, T9B, Newark, NJ 7102 | Generator 4 | 100.00% |
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#200 | Newark Energy Center | Newark, NJ | 3.4 TWh |
#201 | Riverside Energy Center | Beloit, WI | 3.4 TWh |
#202 | J Lamar Stall Unit | Shreveport, LA | 3.4 TWh |
#203 | Kings Mountain Energy Center | Kings Mountain, NC | 3.3 TWh |
#204 | R D Morrow | Purvis, MS | 3.3 TWh |
#205 | Marshalltown Generating Station | Marshalltown, IA | 3.3 TWh |
#206 | Decatur Energy Center | Decatur, AL | 3.3 TWh |
#207 | Ironwood LLC | Lebanon, PA | 3.3 TWh |
#208 | Chattahoochee Energy Facility | Franklin, GA | 3.3 TWh |
#209 | Grays Harbor Energy Facility | Elma, WA | 3.3 TWh |
#211 | Granite Ridge | Londonderry, NH | 3.2 TWh |
#212 | Lost Pines 1 Power Project | Bastrop, TX | 3.2 TWh |
#213 | Cedar Bayou | Baytown, TX | 3.2 TWh |
#214 | Hinds Energy Facility | Jackson, MS | 3.2 TWh |
#215 | Wansley Unit 9 | Franklin, GA | 3.2 TWh |
#216 | Wildcat Point Generation Facility | Conowingo, MD | 3.2 TWh |
#217 | Harrison County Power Project | Marshall, TX | 3.2 TWh |
#218 | Westbrook Energy Center Power Plant | Westbrook, ME | 3.2 TWh |
#219 | Hobbs Generating Station | Hobbs, NM | 3.2 TWh |
#220 | Jack Fusco Energy Center | Thompsons, TX | 3.2 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Bridgeport Station.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Bridgeport Energy Project | Bridgeport, CT | 2.7 TWh | 0.1 mi |
Bridgeport Fuel Cell, LLC | Bridgeport, CT | 105.1 GWh | 1.4 mi |
Derby Fuel Cell | Derby, CT | 8.2 GWh | 11.6 mi |
Derby Hydro | Shelton, CT | 9.3 GWh | 11.4 mi |
Devon Station | Milford, CT | 123.0 MWh | 4.8 mi |
Digital Fairfield | Trumbull, CT | 13.1 GWh | 5.2 mi |
Emerald Gardens PKI, LLC | Shelton, CT | 2.2 GWh | 7.7 mi |
Fairfield University CHP Plant | Fairfield, CT | 25.3 GWh | 3.9 mi |
GenConn Devon LLC | Milford, CT | 2.3 GWh | 4.9 mi |
Milford Power Project | Milford, CT | 3.7 TWh | 5.8 mi |
Norden 1-3 | Norwalk, CT | 42.0 MWh | 11.6 mi |
Norwalk Hospital Plant | Norwalk, CT | 4.3 GWh | 13 mi |
Park Solar | Woodbridge, CT | 20.0 MWh | 15.4 mi |
Port Jefferson | Port Jefferson, NY | 396.4 GWh | 16.2 mi |
Sikorsky Aircraft CHP | Stratford, CT | 64.3 GWh | 7.1 mi |
Stevenson | Monroe, CT | 111.2 GWh | 14.7 mi |
UB Fuel Cell | Bridgeport, CT | 10.5 GWh | 0.7 mi |
UI RCP Bridgeport Seaside | Bridgeport, CT | 19.7 GWh | 1.5 mi |
UI RCP Woodbridge FC | Woodbridge, CT | 16.5 GWh | 15.9 mi |
Wheelabrator Bridgeport | Bridgeport, CT | 453.7 GWh | 1.4 mi |