Anson County Generation Facility
749 Blewett Falls Road, Lilesville, NC 28091Plant Summary Information
Anson County Generation Facility is ranked #14 out of 30 natural gas power plants in North Carolina in terms of total annual net electricity generation.
Anson County Generation Facility is comprised of 6 generators and generated 21.0 GWh during the 3-month period between September 2023 to December 2023.
Plant Name | Anson County Generation Facility |
---|---|
Utility Name | North Carolina El Member Corp |
Location | Anson County, NC |
Initial Operation Date | June 2007 |
Last Update | Dec 2023 |
Annual Generation | 92.2 GWh |
Annual Consumption | 1.6 M MMBtu |
Ranked #3,264 out of 11,835 Power Plants Nationwide | |
Ranked #927 out of 2,253 Natural Gas Power Plants Nationwide | |
Ranked #80 out of 862 North Carolina Power Plants | |
Ranked #14 out of 30 North Carolina Natural Gas Power Plants | |
Fuel Types | Natural Gas : 97.1% Distillate Fuel Oil : 2.9% |
Map of Anson County Generation Facility
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Anson County Generation Facility.
Monthly Net Generation for Anson County Generation Facility
Anson County Generation Facility Details
Summary Information | |
---|---|
Plant Name | Anson County Generation Facility (56249) |
Plant Address | 749 Blewett Falls Road, Lilesville, NC 28091 |
Utility | North Carolina El Member Corp (13683) |
Latitude, Longitude | 34.96865, -79.92174 |
Generation Dates on File | Jun 2007 to Dec 2023 |
Initial Operation Date | June 2007 |
Annual Generation | 92.2 GWh |
Fuel Types | Natural Gas : 97.1% Distillate Fuel Oil : 2.9% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | No |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Regulated |
NERC Region | SERC |
Balancing Authority | Duke Energy Progress East (CPLE) |
NAICS Code | Utilities (22) |
Sector | Electric Utility (1) |
Water Source | County Water |
Ash Impoundment | No |
Transmission / Distribution Owner | Duke Energy Progress - (NC) (3046) NC |
Grid Voltage | 230.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | PIEDMONT NATURAL GAS |
Natural Gas Storage | No |
Generator 1 Details Operating June 2007
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 57.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 56.5 MW |
Winter Capacity | 61.1 MW |
Minimum Load | 28 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2007 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 56.5 MW |
Net Winter Capacity With Natural Gas | 61.1 MW |
Net Summer Capacity With Oil | 54.9 MW |
Net Winter Capacity With Oil | 54.9 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 2 Details Operating June 2007
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 57.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 56.5 MW |
Winter Capacity | 61.1 MW |
Minimum Load | 28 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2007 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 56.5 MW |
Net Winter Capacity With Natural Gas | 61.1 MW |
Net Summer Capacity With Oil | 54.9 MW |
Net Winter Capacity With Oil | 54.9 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 3 Details Operating June 2007
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 57.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 56.5 MW |
Winter Capacity | 61.1 MW |
Minimum Load | 28 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2007 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 56.5 MW |
Net Winter Capacity With Natural Gas | 61.1 MW |
Net Summer Capacity With Oil | 54.9 MW |
Net Winter Capacity With Oil | 54.9 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 4 Details Operating June 2007
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 57.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 56.5 MW |
Winter Capacity | 61.1 MW |
Minimum Load | 28 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2007 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 56.5 MW |
Net Winter Capacity With Natural Gas | 61.1 MW |
Net Summer Capacity With Oil | 54.9 MW |
Net Winter Capacity With Oil | 54.9 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 5 Details Operating June 2007
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 57.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 56.5 MW |
Winter Capacity | 61.1 MW |
Minimum Load | 28 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2007 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 56.5 MW |
Net Winter Capacity With Natural Gas | 61.1 MW |
Net Summer Capacity With Oil | 54.9 MW |
Net Winter Capacity With Oil | 54.9 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Generator 6 Details Operating June 2007
Technology | Natural Gas Fired Combustion Turbine |
---|---|
Prime Mover | Combustion Turbine |
Ownership | Single Owner |
Nameplate Capacity | 57.3 MW |
Nameplate Power Factor | 0.85 |
Summer Capacity | 56.5 MW |
Winter Capacity | 61.1 MW |
Minimum Load | 28 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | June 2007 |
---|---|
Combined Heat & Power | No |
Sector Name | Electric Utility (1) |
Energy Source | Natural Gas / Distillate Fuel Oil |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 1H |
Multiple Fuels | Yes |
Cofire Fuels | No |
Switch Between Oil And Natural Gas | Yes |
Multifuel Details | |
Switch When Operating | Yes |
---|---|
Net Summer Capacity With Natural Gas | 56.5 MW |
Net Winter Capacity With Natural Gas | 61.1 MW |
Net Summer Capacity With Oil | 54.9 MW |
Net Winter Capacity With Oil | 54.9 MW |
Time To Switch From Gas To Oil | 1H |
Time To Switch From Oil To Gas | 1H |
Factors That Limit Switching | Yes |
Storage Limits | Yes |
Air Permit Limits | Yes |
Anson County Generation Facility Plant Owners
Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#917 | Vanderbilt University Power Plant | Nashville, TN | 94.3 GWh |
#918 | West Marinette | Peshtigo, WI | 93.8 GWh |
#919 | CML&P Generating Facility No. 2 | Coffeyville, KS | 93.2 GWh |
#920 | Mariposa Energy Project | Byron, CA | 92.8 GWh |
#921 | Oak Point Cogen | Belle Chasse, LA | 92.8 GWh |
#922 | Harlem River Yard | Bronx, NY | 92.5 GWh |
#923 | Greens Bayou | Houston, TX | 92.3 GWh |
#924 | University of Notre Dame | Notre Dame, IN | 92.2 GWh |
#925 | Pixelle Specialty Solutions LLC - Spring Grove Facility | Spring Grove, PA | 387.5 GWh |
#926 | Bellingham Cogeneration Facility | Bellingham, MA | 102.2 GWh |
#928 | Castleton Energy Center | Castleton, NY | 89.9 GWh |
#929 | Archbald Power Station | Archbald, PA | 112.6 GWh |
#930 | Washington County Power LLC | Sandersville, GA | 88.5 GWh |
#931 | Niland Gas Turbine Plant | Niland, CA | 88.4 GWh |
#932 | Pea Ridge | Pace, FL | 88.4 GWh |
#933 | Stillwater Energy Center | Stillwater, OK | 88.4 GWh |
#934 | Friendswood Energy | Houston, TX | 88.2 GWh |
#935 | Wayne County | Goldsboro, NC | 90.7 GWh |
#936 | Clayville | Vineland, NJ | 87.4 GWh |
#937 | Macon Energy Center | Macon, MO | 87.3 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Anson County Generation Facility.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Blewett | Lilesville, NC | 116.1 GWh | 2.7 mi |
County Home Solar LLC | Rockingham, NC | 9.6 GWh | 11.7 mi |
Ellerbe | Ellerbe, NC | 3.2 GWh | 14.1 mi |
ESA Hamlet NC , LLC | Hamlet, NC | 8.1 GWh | 15.4 mi |
Gilead | Gilead, NC | 6.7 GWh | 16.7 mi |
Hamlet Generating Facility | Hamlet, NC | 76.7 GWh | 13.7 mi |
Hamlet Solar Energy Storage | Hamlet, NC | 252.0 MWh | 13.6 mi |
Innovative Solar 37 LLC | Morven, NC | 118.6 GWh | 9.1 mi |
Mills Anson Farm | Lilesville, NC | 8.7 GWh | 0.8 mi |
Pecan PV1 | Cordova, NC | 9.2 GWh | 6.6 mi |
Polk Farm | Hamlet, NC | 11.1 GWh | 15.5 mi |
Rock Farm | Rockingham, NC | 9.2 GWh | 17.7 mi |
Sellers Farm Solar | Hamlet, NC | 10.6 GWh | 15.7 mi |
Selwyn Farm | Lilesville, NC | 10.9 GWh | 4 mi |
Sherwood H Smith Jr Energy Complex | Hamlet, NC | 8.8 TWh | 13.6 mi |
Wadesboro 4 | Wadesboro, NC | 3.8 GWh | 14.6 mi |
Wadesboro Farm 1 | Wadesboro, NC | 8.6 GWh | 10.1 mi |
Wadesboro Farm 2 | Wadesboro, NC | 9.4 GWh | 10.4 mi |
Wadesboro Farm 3 | Wadesboro, NC | 9.2 GWh | 7.3 mi |
Wadesboro Solar | Wadesboro, NC | 9.4 GWh | 6.1 mi |